Literature DB >> 16118559

The treatment of distal clavicle fractures with coracoclavicular ligament disruption: a report of 10 cases.

Murat Bezer1, Nuri Aydin, Osman Guven.   

Abstract

OBJECTIVE: Fractures of the distal third of the clavicle with coracoclavicular ligament disruption have been associated with delayed union or nonunion. A combined surgical technique for the fracture fixation and ligament repair for acute fractures was developed. The technique includes K-wire fixation and suture anchor placement with Ethibond suture to the coracoid process. The results of this combined technique were evaluated.
DESIGN: Prospective, consecutive case series.
SETTING: Surgical treatment was performed at the Department of Orthopedics and Traumatology. PATIENTS: Ten patients with acute fractures of the distal third of the clavicle were enrolled with a mean follow-up period of 24.1 (range, 12-36) months. INTERVENTION: A single suture anchor was placed on the coracoid process in a vertical position. The Ethibond suture attached to the anchor was used to depress the elevated proximal part of the clavicle by pulling it down to the coracoid process where the anchor was placed. The suture was pulled over the proximal clavicle and tied. The distal fragment was fixed to the proximal clavicle by an intramedullary K-wire. The torn coracoclavicular ligaments were approximated using absorbable suture. MAIN OUTCOME MEASUREMENTS: The patients were evaluated by the Constant scores and Modified Shoulder Rating Scale.
RESULTS: The mean Constant score was 96.6 points in the last follow-up. Nine patients had excellent results, and 1 patient had a good result, using the Modified Shoulder Rating Scale.
CONCLUSIONS: This is a reliable technique with encouraging results for treating displaced distal third clavicle fractures with coracoclavicular ligament disruption.

Entities:  

Mesh:

Year:  2005        PMID: 16118559     DOI: 10.1097/01.bot.0000164593.04348.e5

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  14 in total

1.  What Regions of the Distal Clavicle Have the Greatest Bone Mineral Density and Cortical Thickness? A Cadaveric Study.

Authors:  Raymond E Chen; Sandeep P Soin; Rami El-Shaar; Gregg T Nicandri; Hani A Awad; Michael D Maloney; Ilya Voloshin
Journal:  Clin Orthop Relat Res       Date:  2019-12       Impact factor: 4.176

2.  Modified tension band for displaced type 2 lateral end clavicle fractures.

Authors:  Laxman Rijal; Gopal Sagar; Anshumala Joshi; Khima Nand Joshi
Journal:  Int Orthop       Date:  2012-03-06       Impact factor: 3.075

3.  Precontoured superior locked plating of distal clavicle fractures: a new strategy.

Authors:  Jaron R Andersen; Matt P Willis; Ryan Nelson; Mark A Mighell
Journal:  Clin Orthop Relat Res       Date:  2011-12       Impact factor: 4.176

4.  Fixation method for treatment of unstable distal clavicle fracture: systematic review and network meta-analysis.

Authors:  Manusak Boonard; Sermsak Sumanont; Alisara Arirachakaran; Eakachit Sikarinkul; Pichet Ratanapongpean; Wichan Kanchanatawan; Jatupon Kongtharvonskul
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-03-22

5.  Treatment for unstable distal clavicle fractures (Neer 2) with locking T-plate and additional PDS cerclage.

Authors:  Frank Martetschläger; Tobias M Kraus; Clara Sophie Schiele; Gunther Sandmann; Sebastian Siebenlist; Karl F Braun; Ulrich Stöckle; Thomas Freude; Markus Neumaier
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-01       Impact factor: 4.342

Review 6.  Open coraco-clavicular ligament reconstruction (CCLR) in treatment of displaced distal clavicle fractures has low complication rate and excellent union rate: a systematic review.

Authors:  Shahbaz S Malik; Sheraz Malik; Muaaz Tahir; Robert W Jordan; Hubert Laprus; Peter D'Alessandro
Journal:  Arch Orthop Trauma Surg       Date:  2022-02-18       Impact factor: 3.067

7.  Anatomic locking plate and coracoclavicular stabilization with suture endo-button technique is superior in the treatment of Neer Type II distal clavicle fractures.

Authors:  Mustafa Seyhan; Baris Kocaoglu; Gorkem Kiyak; Arel Gereli; Metin Turkmen
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-03-11

8.  Outcome of distal end clavicle fractures treated with locking plates.

Authors:  Raju Vaishya; Vipul Vijay; Vikram Khanna
Journal:  Chin J Traumatol       Date:  2017-01-20

9.  Surgical treatment of Neer type-II fractures of the distal clavicle: a meta-analysis.

Authors:  Sylvia A Stegeman; Hakan Nacak; Koen H J Huvenaars; Theo Stijnen; Pieta Krijnen; Inger B Schipper
Journal:  Acta Orthop       Date:  2013-03-19       Impact factor: 3.717

10.  Precontoured Clavicular Locking Plate with Broad Lateral End: A Newly Designed Plate for Lateral Third Clavicle Fractures.

Authors:  K C Kapil-Mani; P Acharya; S Arun
Journal:  Malays Orthop J       Date:  2018-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.