Literature DB >> 16116013

Cervical spine motion: a fluoroscopic comparison during intubation with lighted stylet, GlideScope, and Macintosh laryngoscope.

Timothy P Turkstra1, Rosemary A Craen, David M Pelz, Adrian W Gelb.   

Abstract

The question of which is the optimum technique to intubate the trachea in a patient who may have a cervical(C)-spine injury remains unresolved. We compared, using fluoroscopic video, C-spine motion during intubation for Macintosh 3 blade, GlideScope, and Intubating Lighted Stylet, popularly known as the Lightwand or Trachlight. Thirty-six healthy patients were randomized to participate in a crossover trial of either Lightwand or GlideScope to Macintosh laryngoscopy, with in-line stabilization. C-spine motion was examined at the Occiput-C1 junction, C1-2 junction, C2-5 motion segment, and C5-thoracic motion segment during manual ventilation via bag-mask, laryngoscopy, and intubation. Time to intubate was also measured. C-spine motion during bag-mask ventilation was 82% less at the four motion segments studied than during Macintosh laryngoscopy (P < 0.001). C-spine motion using the Lightwand was less than during Macintosh laryngoscopy, averaging 57% less at the four motion segments studied (P < 0.03). There was no significant difference in time to intubate between the Lightwand and the Macintosh blade. C-spine motion was reduced 50% at the C2-5 segment using the GlideScope (P < 0.04) but unchanged at the other segments. Laryngoscopy with GlideScope took 62% longer than with the Macintosh blade (P < 0.01). Thus, the Lightwand (Intubating Lighted Stylet) is associated with reduced C-spine movement during endotracheal intubation compared with the Macintosh laryngoscope.

Entities:  

Mesh:

Year:  2005        PMID: 16116013     DOI: 10.1213/01.ane.0000166975.38649.27

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  44 in total

Review 1.  [Awake fiberoptic intubation].

Authors:  F Gerheuser; K Gürtler
Journal:  Anaesthesist       Date:  2011-12       Impact factor: 1.041

2.  Intubation with simultaneous use of the GlideScope and the Trachlight.

Authors:  Kay B Leissner; Sascha Beutler; Mohamed Hamouda; Ivan Valovski
Journal:  J Anesth       Date:  2008-08-07       Impact factor: 2.078

3.  Comparison of cervical spine motion during intubation with a C‑MAC D‑Blade® and an LMA Fastrach®.

Authors:  D Özkan; S Altınsoy; M Sayın; H Dolgun; J Ergil; A Dönmez
Journal:  Anaesthesist       Date:  2019-01-09       Impact factor: 1.041

4.  A Comparison of the Effects of Different Types of Laryngoscope on the Cervical Motions: Randomized Clinical Trial.

Authors:  Alkin Çolak; Elif Çopuroğlu; Ali Yılmaz; Sevtap Hekimoğlu Şahin; Nesrin Turan
Journal:  Balkan Med J       Date:  2015-04-01       Impact factor: 2.021

5.  A comparison of single-handed chin lift and two-handed jaw thrust for tracheal intubation using a lightwand.

Authors:  Seong-Mi Yang; Hyerim Kim; Jee-Eun Chang; Seong-Won Min; Jung-Man Lee; Jin-Young Hwang
Journal:  J Anesth       Date:  2016-11-01       Impact factor: 2.078

6.  Managing difficult airway in patients with post-burn mentosternal and circumoral scar contractures.

Authors:  Tae-Hyung Han; Hana Teissler; Richard J Han; Joshua D Gaines; Tho Qynh Nguyen
Journal:  Int J Burns Trauma       Date:  2012-09-15

7.  Emergency Neurological Life Support: Airway, Ventilation, and Sedation.

Authors:  Venkatakrishna Rajajee; Becky Riggs; David B Seder
Journal:  Neurocrit Care       Date:  2017-09       Impact factor: 3.210

8.  Distortion of anterior airway anatomy during laryngoscopy with the GlideScope videolaryngoscope.

Authors:  Yoshihiro Hirabayashi; Akifumi Fujita; Norimasa Seo; Hideharu Sugimoto
Journal:  J Anesth       Date:  2010-04-06       Impact factor: 2.078

9.  Advances in laryngoscopy: rigid indirect laryngoscopy.

Authors:  Deanne R Cheyne; Patrick Doyle
Journal:  F1000 Med Rep       Date:  2010-08-19

10.  A comparison of 4 airway devices on cervical spine alignment in cadaver models of global ligamentous instability at c1-2.

Authors:  Adam L Wendling; Patrick J Tighe; Bryan P Conrad; Tezcan Ozrazgat Baslanti; Marybeth Horodyski; Glenn R Rechtine
Journal:  Anesth Analg       Date:  2013-01-25       Impact factor: 5.108

View more