A case study of radiotherapy planning for a bilateral metal hip prosthesis prostate cancer patient.

Andy Su1, Chester Reft, Carla Rash, Jennifer Price, Ashesh B Jani.   

Abstract

The purpose of this report is to communicate the observed advantage of intensity-modulated radiotherapy (IMRT) in a patient with bilateral metallic hip prostheses. In this patient with early-stage low-risk disease, a dose of 74 Gy was planned in two phases--an initial 50 Gy to the prostate and seminal vesicles and an additional 24 Gy to the prostate alone. Each coplanar beam avoided the prosthesis in the beam's eye view. Using the same target expansions for each phase, IMRT and 3D-conformal radiotherapy (CRT) plans were compared for target coverage and inhomogeneity as well as dose to the bladder and rectum. The results of the analysis demonstrated that IMRT provided superior target coverage with reduced dose to normal tissues for both individual phases of the treatment plan as well as for the composite treatment plan. The dose to the rectum was significantly reduced with the IMRT technique, with a composite V 80 of 35% for the IMRT plan versus 70% for 3D-CRT plan. Similarly, the dose to the bladder was significantly reduced with a V 80 of 9% versus 20%. Overall, various dosimetric parameters revealed the corresponding 3D-CRT plan would not have been acceptable. The results indicate significant success with IMRT in a clinical scenario where there were no curative alternatives for local treatment other than external beam radiotherapy. Therefore, definitive external beam radiation of prostate cancer patients with bilateral prosthesis is made feasible with IMRT. The work described herein may also have applicability to other groups of patients, such as those with gynecological or other pelvic malignancies.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16112469     DOI: 10.1016/j.meddos.2005.06.001

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  10 in total

1.  Volumetric modulated arc therapy for prostate cancer patients with hip prosthesis.

Authors:  Ramachandran Prabhakar; Milind Kumar; Suja Cheruliyil; Silpa Jayakumar; Satheesan Balasubramanian; Jim Cramb
Journal:  Rep Pract Oncol Radiother       Date:  2013-04-28

2.  Volumetric modulated arc therapy in prostate cancer patients with metallic hip prostheses in a UK centre.

Authors:  Wee Loon Ng; John Brunt; Simon Temple; Mohammed Saipillai; Anoop Haridass; Helen Wong; Zafar Malik; Chinnamani Eswar
Journal:  Rep Pract Oncol Radiother       Date:  2015-04-14

3.  Evaluation of the radiotherapy treatment planning in the presence of a magnetic valve tissue expander.

Authors:  Débora M Trombetta; Simone C Cardoso; Victor G L Alves; Alessandro Facure; Delano V S Batista; Ademir X da Silva
Journal:  PLoS One       Date:  2015-02-13       Impact factor: 3.240

Review 4.  Computed tomography imaging parameters for inhomogeneity correction in radiation treatment planning.

Authors:  Indra J Das; Chee-Wai Cheng; Minsong Cao; Peter A S Johnstone
Journal:  J Med Phys       Date:  2016 Jan-Mar

5.  An opposed matched field IMRT technique for prostate cancer patients with bilateral prosthetic hips.

Authors:  Shahin Fattahi; Orest Z Ostapiak
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

Review 6.  ACR Appropriateness Criteria® external beam radiation therapy treatment planning for clinically localized prostate cancer, part I of II.

Authors:  Nicholas G Zaorsky; Timothy N Showalter; Gary A Ezzell; Paul L Nguyen; Dean G Assimos; Anthony V D'Amico; Alexander R Gottschalk; Gary S Gustafson; Sameer R Keole; Stanley L Liauw; Shane Lloyd; Patrick W McLaughlin; Benjamin Movsas; Bradley R Prestidge; Al V Taira; Neha Vapiwala; Brian J Davis
Journal:  Adv Radiat Oncol       Date:  2016-10-20

7.  Dose comparison between Gafchromic film, XiO, and Monaco treatment planning systems in a novel pelvic phantom that contains a titanium hip prosthesis.

Authors:  Nicholas Ade; F C P du Plessis
Journal:  J Appl Clin Med Phys       Date:  2017-07-25       Impact factor: 2.102

8.  Dosimetry Effects Caused by Unilateral and Bilateral Hip Prostheses: A Monte Carlo Case Study in Megavoltage Photon Radiotherapy for Computed Tomography Data without Metal Artifacts.

Authors:  Courage Mahuvava; Frederik Carl Phillipus Du Plessis
Journal:  J Med Phys       Date:  2018 Oct-Dec

9.  A dosimetric study of volumetric modulated arc therapy planning techniques for treatment of low-risk prostate cancer in patients with bilateral hip prostheses.

Authors:  Suresh B Rana; Shyam Pokharel
Journal:  South Asian J Cancer       Date:  2014-01

10.  Dosimetric study of uniform scanning proton therapy planning for prostate cancer patients with a metal hip prosthesis, and comparison with volumetric-modulated arc therapy.

Authors:  Suresh Rana; ChihYao Cheng; Yuanshui Zheng; Wen Hsi; Omar Zeidan; Niek Schreuder; Carlos Vargas; Gary Larson
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.