Literature DB >> 16109327

Association of risk factors with increased pulse wave velocity detected by a novel method using dual-channel photoplethysmography.

Wei-Chuan Tsai1, Ju-Yi Chen, Ming-Chen Wang, Hsien-Tsai Wu, Chih-Kai Chi, Yung-Kung Chen, Jyh-Hong Chen, Li-Jen Lin.   

Abstract

BACKGROUND: Pulse wave velocity (PWV) is correlated with cardiovascular risk. This study presents a new method for measuring the arterial PWV by simultaneously recording the digital volume pulse through the finger and the toe by way of dual-channel photoplethysmography (PPG).
METHODS: In this study, 100 asymptomatic subjects (54 men and 46 women, 19 to 64 years of age) were enrolled. The PWV was measured both by dual-channel PPG (PWV-DVP) and by the standard method that current used applanation tonometry (PWV-AT). The developed dual-channel PPG system recorded digital volume pulse simultaneously from both the finger and toe. Time of pulse transition was measured on the time delay difference between two digital volume pulses. The PWV was calculated by dividing the distance between finger and toe by that of transit time.
RESULTS: The PWV-DVP was significantly correlated with PWV-AT (r = 0.678, P < .01). With multivariate analysis controlled for age, heart rate, systolic blood pressure, and diastolic blood pressure, PWV-DVP was still significantly correlated with PWV-AT (r = 0.669, P < .01). Subjects with hypertension and dyslipidemia had significant higher PWV detected by both methods.
CONCLUSION: This study showed that PWV measured with dual-channel PPG system correlated very well with that measured using the traditional method.

Entities:  

Mesh:

Year:  2005        PMID: 16109327     DOI: 10.1016/j.amjhyper.2005.03.739

Source DB:  PubMed          Journal:  Am J Hypertens        ISSN: 0895-7061            Impact factor:   2.689


  12 in total

1.  Measuring pulse wave velocity using ECG and photoplethysmography.

Authors:  An-Bang Liu; Po-Chun Hsu; Zong-Li Chen; Hsien-Tsai Wu
Journal:  J Med Syst       Date:  2010-04-06       Impact factor: 4.460

2.  Factors that affect pulse wave time transmission in the monitoring of cardiovascular system.

Authors:  Jong Yong A Foo; Stephen J Wilson; Ping Wang
Journal:  J Clin Monit Comput       Date:  2008-03-19       Impact factor: 2.502

3.  Assessment of Subtle Changes in Diabetes-Associated Arteriosclerosis using Photoplethysmographic Pulse Wave from Index Finger.

Authors:  Po-Chun Hsu; Hsien-Tsai Wu; Cheuk-Kwan Sun
Journal:  J Med Syst       Date:  2018-01-24       Impact factor: 4.460

4.  Uric acid is an independent predictor of arterial stiffness in hypertensive patients.

Authors:  Wei-Chuan Tsai; Yao-Yi Huang; Chih-Chan Lin; Wei-Ting Li; Cheng-Han Lee; Ju-Yi Chen; Jyh-Hong Chen
Journal:  Heart Vessels       Date:  2009-09-27       Impact factor: 2.037

5.  Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera.

Authors:  In Cheol Jeong; Joseph Finkelstein
Journal:  J Med Syst       Date:  2016-01-20       Impact factor: 4.460

6.  Difference between ejection times measured at two different peripheral locations as a novel marker of vascular stiffness.

Authors:  Yurie Obata; Pavel Ruzankin; Dan E Berkowitz; Jochen Steppan; Viachaslau Barodka
Journal:  PLoS One       Date:  2017-11-29       Impact factor: 3.240

7.  Percussion Entropy Analysis of Synchronized ECG and PPG Signals as a Prognostic Indicator for Future Peripheral Neuropathy in Type 2 Diabetic Subjects.

Authors:  Hai-Cheng Wei; Na Ta; Wen-Rui Hu; Sheng-Ying Wang; Ming-Xia Xiao; Xiao-Jing Tang; Jian-Jung Chen; Hsien-Tsai Wu
Journal:  Diagnostics (Basel)       Date:  2020-01-09

8.  Multi-Site Photoplethysmographic and Electrocardiographic System for Arterial Stiffness and Cardiovascular Status Assessment.

Authors:  David Perpetuini; Antonio Maria Chiarelli; Lidia Maddiona; Sergio Rinella; Francesco Bianco; Valentina Bucciarelli; Sabina Gallina; Vincenzo Perciavalle; Vincenzo Vinciguerra; Arcangelo Merla; Giorgio Fallica
Journal:  Sensors (Basel)       Date:  2019-12-17       Impact factor: 3.576

9.  In vivo assessment of endothelial function in small animals using an infrared pulse detector.

Authors:  Cyuan-Cin Liu; Wei-Min Liu; Hsien-Tsai Wu; Chien-Hsing Wang; An-Bang Liu
Journal:  Ci Ji Yi Xue Za Zhi       Date:  2019-09-16

Review 10.  Assessing hemodynamics from the photoplethysmogram to gain insights into vascular age: a review from VascAgeNet.

Authors:  Peter H Charlton; Birutė Paliakaitė; Kristjan Pilt; Martin Bachler; Serena Zanelli; Dániel Kulin; John Allen; Magid Hallab; Elisabetta Bianchini; Christopher C Mayer; Dimitrios Terentes-Printzios; Verena Dittrich; Bernhard Hametner; Dave Veerasingam; Dejan Žikić; Vaidotas Marozas
Journal:  Am J Physiol Heart Circ Physiol       Date:  2021-12-24       Impact factor: 4.733

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.