Literature DB >> 16106119

Vascular thrombosis during support with continuous flow ventricular assist devices: correlation with computerized flow simulations.

Biswajit Kar1, Reynolds M Delgado, Branislav Radovancevic, Timothy J Myers, Yasmin Wadia, George V Letsou, Imran Riaz, Ralph Metcalfe, Igor Gregoric, Matthew T Harting.   

Abstract

Continuous flow pumps are increasingly used to treat severe heart failure. These pumps alter flow physiology by lowering pulsatility in the arterial circulation. In patients with peripheral stenosis, continuous flow pumps may lead to thrombosis of peripheral vessels, possibly predisposing to vascular thrombosis in areas of non-flow-limiting stenosis. The authors performed a computerized flow modeling simulation to analyze the effects of altered hemodynamics in a stenotic area. Drawing on previous clinical experience, we modeled a stenotic area in the common carotid artery. Computerized flow modeling revealed blood stagnation zones with low shear stress and velocity adjacent to the stenotic area during nonpulsatile flow. Such stagnation was not present during pulsatile flow. These results indicate a mechanism by which altered physiologic flow may accelerate occlusion of arterial conduits in patients with preexisting stenosis. This finding may be important for patients with continuous flow devices who have peripheral vascular disease; therefore, further study is warranted.

Entities:  

Mesh:

Year:  2005        PMID: 16106119     DOI: 10.1111/j.1527-5299.2005.04474.x

Source DB:  PubMed          Journal:  Congest Heart Fail        ISSN: 1527-5299


  4 in total

Review 1.  In Vitro models for thrombogenicity testing of blood-recirculating medical devices.

Authors:  Deepika N Sarode; Shuvo Roy
Journal:  Expert Rev Med Devices       Date:  2019-06-10       Impact factor: 3.166

2.  Hemodynamics in a cerebral artery before and after the formation of an aneurysm.

Authors:  A Mantha; C Karmonik; G Benndorf; C Strother; R Metcalfe
Journal:  AJNR Am J Neuroradiol       Date:  2006-05       Impact factor: 3.825

3.  Thinking Outside the Heart: Use of Engineered Cardiac Tissue for the Treatment of Chronic Deep Venous Insufficiency.

Authors:  Narine Sarvazyan
Journal:  J Cardiovasc Pharmacol Ther       Date:  2014-02-04       Impact factor: 2.457

4.  Point-of-Care Rapid-Seeding Ventricular Assist Device with Blood-Derived Endothelial Cells to Create a Living Antithrombotic Coating.

Authors:  Maria Noviani; Ryan M Jamiolkowski; Justin E Grenet; Qiuyu Lin; Tim A Carlon; Le Qi; Alexandra E Jantzen; Carmelo A Milano; George A Truskey; Hardean E Achneck
Journal:  ASAIO J       Date:  2016 Jul-Aug       Impact factor: 2.872

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.