STUDY
OBJECTIVE: Previous studies suggest a correlation of central venous pressure (CVP) with peripheral venous pressure (PVP) in different clinical setups. The aim of this study was to investigate the effect of measurement site on PVP and its agreement with CVP in patients undergoing general anesthesia.
DESIGN: Prospective randomized study. SETTINGS: University hospital. PATIENTS: Thirty patients of American Society of Anesthesiologists physical status I and II undergoing elective craniotomy.
INTERVENTIONS: Patients were randomly assigned into Group A (antecubital; n=15) and Group D (dorsum hand; n=15) for antecubital and hand dorsum catheterization sites, respectively. Central venous pressure and PVP were monitored throughout the study. A total of 1925 simultaneous measurements were recorded at 5-minute intervals. Bland-Altman assessment for agreement was used for CVP and PVP in 2 groups. MEASUREMENTS: Peripheral venous pressure measurements were within the range of +/-2 mm Hg of CVP values, in 93.9% of the measurements in Group A, and in 91.2% of the measurements in Group D. Considering all measurements, mean bias was -0.072 mm Hg (95% CI, -0.134 to -0.010). Group A measurements showed a bias (CVP-PVP) of 0.173+/-3.557 mm Hg, whereas the bias was -0.122+/-4.322 mm Hg (mean+/-SDcorrected for repeated measurements) in Group D. All of the measurements were within mean+/-2SD of bias, which means that PVP and CVP are interchangeable in our clinical setting.
CONCLUSION: Peripheral venous pressure measurement may be a noninvasive alternative for estimating CVP in patients undergoing elective neurosurgical operations. Measuring PVP from hand dorsum does not interfere with the agreement of CVP and PVP.

Entities:  

Mesh:

Year:  2005        PMID: 16102684     DOI: 10.1016/j.jclinane.2004.08.015

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  2 in total

1.  Analysis of central venous pressure (CVP) signals using mathematical methods.

Authors:  Parham Atefvahid; Kamran Hassani; Kamal Jafarian; D John Doyle; Hessam Ahmadi
Journal:  J Clin Monit Comput       Date:  2016-05-03       Impact factor: 2.502

2.  Peripheral venous pressure as a reliable predictor for monitoring central venous pressure in patients with burns.

Authors:  Lulu Sherif; Vikas S Joshi; Anjali Ollapally; Prithi Jain; Kishan Shetty; Karl Sa Ribeiro
Journal:  Indian J Crit Care Med       Date:  2015-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.