Literature DB >> 16097224

Molar distalization with a modified pendulum appliance--in vitro analysis of the force systems and in vivo study in children and adolescents.

Gero S M Kinzinger1, Heiner Wehrbein, Peter R Diedrich.   

Abstract

The standard pendulum appliance was modified by integrating a distal screw into its base and by special preactivation of the pendulum springs. The suitability of this Pendulum K for the translatory distalization of maxillary molars was investigated in an in vitro analysis and in an in vivo study in children and adolescents. The in vitro measurement of the resulting force systems revealed that all forces and moments remained virtually constant over a three-mm simulated distalization increment. The transverse force, Fx, increased from two to 11 cN and the weakly intrusively acting force, Fy, from six to eight cN, but these increases were not statistically significant. The distalization force, Fz, initially 201 cN, was still 199 cN after a three-mm distalization increment. The mesially acting moment, My, rose from 1654 to 1834 cN mm, whereas the palatally acting moment, Mz, declined slightly from 229 to 164 cN mm. The slight, consistent distoinclinatory moment, Mx, initially 306 cN mm, was 310 cN mm after three mm. In parallel, the in vivo study with its collective of 66 patients confirmed that the Pendulum K allows a virtually translatory molar distalization with slight tippings of 4.75 degrees to the palatal plane and 4.25 degrees to the anterior basal plane. Palatal movements of the first molars were avoided. The proportion of molar distalization in the total movement was 73.53%.

Entities:  

Mesh:

Year:  2005        PMID: 16097224     DOI: 10.1043/0003-3219(2005)75[558:MDWAMP]2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  11 in total

1.  Effects of conventional anchorage on premolar root development during treatment with a pendulum appliance.

Authors:  Gero Kinzinger; Cora Pantel; Björn Ludwig; Norbert Gülden; Bettina Glasl; Jörg Lisson
Journal:  J Orofac Orthop       Date:  2010-07-30       Impact factor: 1.938

2.  Evaluation of the effects of the hybrid Pendulum in comparison with the conventional Pendulum appliance.

Authors:  Erdal Bozkaya; Tuba Tortop; Sema Yüksel; Emine Kaygısız
Journal:  Angle Orthod       Date:  2019-10-23       Impact factor: 2.079

3.  Treatment efficiency of mini-implant-borne distalization depending on age and second-molar eruption.

Authors:  M Nienkemper; B Wilmes; A Pauls; S Yamaguchi; B Ludwig; D Drescher
Journal:  J Orofac Orthop       Date:  2014-03-02       Impact factor: 1.938

4.  Cephalometric effects of the Jones Jig appliance followed by fixed appliances in Class II malocclusion treatment.

Authors:  Mayara Paim Patel; José Fernando Castanha Henriques; Karina Maria Salvatore Freitas; Roberto Henrique da Costa Grec
Journal:  Dental Press J Orthod       Date:  2014 May-Jun

5.  Evaluation of Dentoalveolar and Dentofacial Effects of a Mini-Screw-Anchored Pendulum Appliance in Maxillary Molar Distalization.

Authors:  Mümin Kırcalı; Alime Sema Yüksel
Journal:  Turk J Orthod       Date:  2018-12-01

6.  Long-term evaluation of the molar movements following Pendulum and fixed appliances.

Authors:  Alberto Caprioglio; Mattia Fontana; Elena Longoni; Mauro Cozzani
Journal:  Angle Orthod       Date:  2012-10-18       Impact factor: 2.079

7.  Occlusal Plane Changes After Molar Distalization With a Pendulum Appliance in Growing Patients with Class II Malocclusion: A Retrospective Cephalometric Study.

Authors:  Marco Serafin; Rosamaria Fastuca; Elisabetta Castellani; Alberto Caprioglio
Journal:  Turk J Orthod       Date:  2021-02-23

8.  Comparison of transverse dental changes induced by the palatally applied Frog appliance and buccally applied Karad's integrated distalizing system.

Authors:  Fatma Deniz Uzuner; Emine Kaygisiz; Fatih Unver; Tuba Tortop
Journal:  Korean J Orthod       Date:  2016-03-18       Impact factor: 1.372

9.  Molar distalization with 2K appliance: one-year follow-up.

Authors:  Tulika Tripathi; Priyank Rai; Navneet Singh
Journal:  J Orthod Sci       Date:  2017 Jul-Sep

10.  Cone-beam computed tomography-guided three-dimensional evaluation of treatment effectiveness of the Frog appliance.

Authors:  Mujia Li; Xiaoxia Su; Yang Li; Xianglin Li; Xinqin Si
Journal:  Korean J Orthod       Date:  2019-05-21       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.