Literature DB >> 1609586

Polyethylene wear of the PCA unicompartmental knee. Prospective 5 (4-8) year study of 120 arthrosis knees.

A Lindstrand1, A Stenström.   

Abstract

In Lund, 120 arthrosis knees had the PCA unicompartmental endoprosthesis during 1983-1987 and were followed prospectively for 5 (4-8) years. 17 knees were excluded from the final clinical follow-up because of the development of rheumatoid arthritis (2), severe neurologic disease (3), or death (12). Subjectively, 68 knees were much improved, 26 improved and 9 had failed. First-steps problems were only present in the uncemented group of 49 knees. Of the 9 failures (7 cemented and 2 uncemented) 6 were revised. The main reason for revision was loosening of the femoral component (2), tibial component (2), or both components (1), and polyethylene wear (1). However, all revised tibial components showed polyethylene wear, in 4 quite pronounced. Weight-bearing radiographs (61 knees) revealed major polyethylene wear in an additional 14 knees; not only in thin tibial components. There may be an increasing clinical problem due to polyethylene wear. With the presented findings the PCA unicompartmental knee endoprosthesis cannot be recommended.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1609586     DOI: 10.3109/17453679209154778

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  6 in total

1.  [AMC unicondylar prosthesis].

Authors:  G Saxler; D Temmen; G Bontemps
Journal:  Orthopade       Date:  2004-11       Impact factor: 1.087

2.  Severe metallosis after unicompartmental knee arthroplasty.

Authors:  Vicente Sanchis-Alfonso
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-10-07       Impact factor: 4.342

3.  The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty.

Authors:  Ralf E Rosenberger; Christian Fink; Sebastian Quirbach; Rene Attal; Katja Tecklenburg; Christian Hoser
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-09-20       Impact factor: 4.342

Review 4.  Cementless fixation in medial unicompartmental knee arthroplasty: a systematic review.

Authors:  S Campi; H G Pandit; C A F Dodd; D W Murray
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-07-19       Impact factor: 4.342

5.  Retrieved Unicompartmental Implants with Full PE Tibial Components: The Effects of Knee Alignment and Polyethylene Thickness on Creep and Wear.

Authors:  Ph Hernigou; A Poignard; P Filippini; S Zilber
Journal:  Open Orthop J       Date:  2008-04-11

6.  Variable bone mineral density reductions post-unicompartmental knee arthroplasty.

Authors:  Mahmut Tuncer; Rajesh Patel; Justin P Cobb; Ulrich N Hansen; Andrew A Amis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-04-27       Impact factor: 4.342