Early clinical results of St. Jude Medical Symmetry aortic connector.

Masashi Toyama1, Akihiko Usui, Tomonobu Abe, Masaharu Yoshikawa, Toshiaki Akita, Yuichi Ueda.   

Abstract

An automated anastomosis device named St. Jude Medical symmetry aortic connector has been used worldwide for off-pump coronary artery bypass grafting. However, early graft obstruction was recently reported, and its predictors should be clarified. From April 2002 to March 2004, 38 patients in our institution underwent off-pump coronary artery bypass grafting using the St. Jude Medical Symmetry aortic connector for saphenous vein graft (SVG) procedures; measurement of intraoperative graft flow and postoperative coronary angiography was performed. Early SVG events occurred in 9 (24%) patients: 8 occlusion cases and 1 case of stenosis. Predictors of early SVG events were assessed from a comparative study. Univariate logistic regression identified hyperlipidemia as the only significant predictor of early SVG events (P = 0.02, odds ratio 7.78). Lower SVG flow rate and poor ejection fraction did not show statistical significance (P = 0.09, odds ratio 1.09 and P = 0.09, odds ratio 0.96). The SVG event rate was much higher for the left circumflex branch compared with other locations (31% vs. 9%, P = 0.03) and decreased with increasing aortic connector size (small, 32%; median, 14%; large, 0%). Multivariate analysis did not identify a predictor of SVG events. The aortic connector is associated with a high incidence of early SVG events. Patients should be cautiously selected and the procedure should not be used for left anterior descending coronary artery or culprit lesions.

Entities:  

Mesh:

Year:  2005        PMID: 16094513     DOI: 10.1007/s10047-005-0293-0

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  12 in total

1.  Graft occlusion after deployment of the Symmetry Bypass System.

Authors:  Oliver T Reuthebuch; Alexander Kadner; Mario L Lachat; Marko I Turina
Journal:  Ann Thorac Surg       Date:  2003-05       Impact factor: 4.330

2.  Coronary anastomotic devices: blood-exposed non-intimal surface and coronary wall stress.

Authors:  Jules S Scheltes; Carolien J van Andel; Peter V Pistecky; Cornelius Borst
Journal:  J Thorac Cardiovasc Surg       Date:  2003-07       Impact factor: 5.209

3.  Flow dynamics of the St Jude Medical Symmetry aortic connector vein graft anastomosis do not contribute to the risk of acute thrombosis.

Authors:  A Redaelli; F Maisano; G Ligorio; E Cattaneo; F M Montevecchi; O Alfieri
Journal:  J Thorac Cardiovasc Surg       Date:  2004-07       Impact factor: 5.209

Review 4.  Clinical experience with devices for facilitated anastomoses in coronary artery bypass surgery.

Authors:  Thierry P Carrel; Friedrich S Eckstein; Lars Englberger; Pascal A Berdat; Jürg Schmidli
Journal:  Ann Thorac Surg       Date:  2004-03       Impact factor: 4.330

5.  The effect of aggressive lowering of low-density lipoprotein cholesterol levels and low-dose anticoagulation on obstructive changes in saphenous-vein coronary-artery bypass grafts.

Authors: 
Journal:  N Engl J Med       Date:  1997-01-16       Impact factor: 91.245

Review 6.  Aortocoronary saphenous vein graft disease: pathogenesis, predisposition, and prevention.

Authors:  J G Motwani; E J Topol
Journal:  Circulation       Date:  1998-03-10       Impact factor: 29.690

7.  Factors affecting saphenous vein graft patency: clinical and angiographic study in 1402 symptomatic patients operated on between 1977 and 1999.

Authors:  Pallav J Shah; Ian Gordon; John Fuller; Siven Seevanayagam; Alex Rosalion; James Tatoulis; Jai S Raman; Brian F Buxton
Journal:  J Thorac Cardiovasc Surg       Date:  2003-12       Impact factor: 5.209

8.  Clinical, angiographic, and interventional follow-up of patients with aortic-saphenous vein graft connectors.

Authors:  Jay H Traverse; Michael R Mooney; Wesley R Pedersen; James D Madison; Thomas F Flavin; Vibhu R Kshettry; Timothy D Henry; Frazier Eales; Lyle D Joyce; Robert W Emery
Journal:  Circulation       Date:  2003-07-14       Impact factor: 29.690

9.  Angiographic results after the use of a sutureless aortic connector for proximal vein graft anastomoses.

Authors:  Lars Wiklund; Mogens Bugge; Eva Berglin
Journal:  Ann Thorac Surg       Date:  2002-06       Impact factor: 4.330

10.  Risk factors in coronary atherosclerosis athero-inflammation: the meeting point.

Authors:  Raul Altman
Journal:  Thromb J       Date:  2003-07-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.