Literature DB >> 1609382

Mediastinal malignancy: ultrasound guided biopsy through the supraclavicular approach.

P C Yang1, D B Chang, Y C Lee, C J Yu, S H Kuo, K T Luh.   

Abstract

BACKGROUND: Malignancies located in the upper middle mediastinum usually do not have a sufficiently large acoustic window to permit a conventional ultrasound guided parasternal biopsy. This study was concerned with an alternative approach whereby ultrasound is applied through the supraclavicular paratracheal window to allow percutaneous biopsy of middle mediastinal malignancies.
METHODS: Fifteen patients who had upper mediastinal malignancies not in contact with the chest wall underwent real time and Doppler ultrasonographic studies by the supraclavicular approach. None of these tumours could be reached by conventional ultrasound guided parasternal biopsy. The ultrasound was scanned downwards through the supraclavicular fossa, along the acoustic window of the paratracheal soft tissue space. Percutaneous aspiration biopsy was performed with a 22 gauge needle under ultrasound guidance. If fine needle aspiration could not obtain an adequate tissue smear an 18 gauge Trucut biopsy was performed to obtain a histological diagnosis.
RESULTS: Twelve of 15 mediastinal malignancies were detected by ultrasound through the supraclavicular approach. These 12 patients underwent percutaneous needle aspiration biopsy under ultrasound guidance. Four of the patients also had a Trucut biopsy because the needle aspirates from the tumours were inadequate. The needle had to pass through the jugular veins in four patients who received fine needle aspiration but in none of the patients who required a Trucut biopsy. Definite histological diagnoses were obtained in all 12 of these patients. Ten of the tumours were malignant and two benign. None of the patients developed any complication.
CONCLUSIONS: Ultrasound and ultrasound guided biopsy through the supraclavicular paratracheal window provides a new approach for malignancy located in the upper middle mediastinum, which cannot be reached by conventional ultrasound guided parasternal biopsy. The diagnostic yield of this technique is high and the procedure is relatively safe.

Entities:  

Mesh:

Year:  1992        PMID: 1609382      PMCID: PMC463758          DOI: 10.1136/thx.47.5.377

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  14 in total

1.  Ultrasonically guided needle biopsy in the diagnosis of mediastinal masses.

Authors:  T Saito; H Kobayashi; Y Sugama; S Tamaki; T Kawai; S Kitamura
Journal:  Am Rev Respir Dis       Date:  1988-09

Review 2.  Percutaneous transthoracic needle biopsy.

Authors:  J L Westcott
Journal:  Radiology       Date:  1988-12       Impact factor: 11.105

3.  Ultrasonically guided percutaneous mediastinal cytology and biopsy.

Authors:  C R Chen; L N Lee; S H Kuo; K T Luh
Journal:  Taiwan Yi Xue Hui Za Zhi       Date:  1986-06

4.  Lung tumors associated with obstructive pneumonitis: US studies.

Authors:  P C Yang; K T Luh; H D Wu; D B Chang; L N Lee; S H Kuo; S P Yang
Journal:  Radiology       Date:  1990-03       Impact factor: 11.105

5.  Peripheral pulmonary lesions: ultrasonography and ultrasonically guided aspiration biopsy.

Authors:  P C Yang; K T Luh; J C Sheu; S H Kuo; S P Yang
Journal:  Radiology       Date:  1985-05       Impact factor: 11.105

6.  Difficult thoracic lesions: CT-guided biopsy experience in 150 cases.

Authors:  E vanSonnenberg; G Casola; M Ho; C C Neff; R R Varney; G R Wittich; R Christensen; P J Friedman
Journal:  Radiology       Date:  1988-05       Impact factor: 11.105

7.  Aspiration needle biopsy of thoracic lesions.

Authors:  T R Todd; G Weisbrod; L C Tao; D E Sanders; N C Delarue; D W Chamberlain; R Ilves; F G Pearson; W Cass; J D Cooper
Journal:  Ann Thorac Surg       Date:  1981-08       Impact factor: 4.330

8.  Mediastinal tumors: biopsy under US guidance.

Authors:  K Wernecke; P Vassallo; P E Peters; D B von Bassewitz
Journal:  Radiology       Date:  1989-08       Impact factor: 11.105

9.  Percutaneous needle aspiration of hilar and mediastinal masses.

Authors:  J L Westcott
Journal:  Radiology       Date:  1981-11       Impact factor: 11.105

10.  Evaluation of ultrasonically guided biopsies of mediastinal masses.

Authors:  C J Yu; P C Yang; D B Chang; H D Wu; L N Lee; Y C Lee; S H Kuo; K T Luh
Journal:  Chest       Date:  1991-08       Impact factor: 9.410

View more
  7 in total

1.  Contrast-enhanced US-guided percutaneous biopsy of anterior mediastinal lesions.

Authors:  Dong Yi; Mao Feng; Wang Wen Ping; Ji Zheng Biao; Pei Li Fan
Journal:  Diagn Interv Radiol       Date:  2017 Jan-Feb       Impact factor: 2.630

2.  Safety and Efficacy of Percutaneous Image-Guided Mediastinal Mass Core-Needle Biopsy.

Authors:  Patrick J Navin; Nathan L Eickstaedt; Thomas D Atwell; Jason R Young; Patrick W Eiken; Brian T Welch; John J Schmitz; Grant D Schmit; Matthew P Johnson; Michael R Moynagh
Journal:  Mayo Clin Proc Innov Qual Outcomes       Date:  2021-11-25

3.  Carcinoid tumours of the thymus.

Authors:  D Y Wang; D B Chang; S H Kuo; P C Yang; Y C Lee; H C Hsu; K T Luh
Journal:  Thorax       Date:  1994-04       Impact factor: 9.139

4.  Transthoracic needle biopsy of thoracic tumours by a colour Doppler ultrasound puncture guiding device.

Authors:  H C Wang; C J Yu; D B Chang; A Yuan; Y C Lee; P C Yang; S H Kuo; K T Luh
Journal:  Thorax       Date:  1995-12       Impact factor: 9.139

5.  Sonographic management of mediastinal syndrome.

Authors:  M Caremani; A Benci; D Tacconi; U Occhini; L Lapini; A Caremani
Journal:  J Ultrasound       Date:  2009-04-29

6.  Diagnostic value and safety of color doppler ultrasound-guided transthoracic core needle biopsy of thoracic disease.

Authors:  Weina Huang; Libin Chen; Ning Xu; Linfeng Wang; Fang Liu; Shiyi He; Tianwen Lai; Xueqin Chen
Journal:  Biosci Rep       Date:  2019-06-07       Impact factor: 3.840

7.  Diagnostic value and complication rate of ultrasound-guided transthoracic core needle biopsy in mediastinal lesions.

Authors:  Rosen Petkov; Tzvetan Minchev; Yordanka Yamakova; Evgeni Mekov; Georgi Yankov; Danail Petrov
Journal:  PLoS One       Date:  2020-04-16       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.