Literature DB >> 16089176

Relationship of feline bispectral index to multiples of isoflurane minimum alveolar concentration.

Leigh A Lamont1, Stephen A Greene, Kurt A Grimm, William J Tranquilli.   

Abstract

The study reported here was done to determine the relationship between bispectral index (BIS) values and minimum alveolar concentration (MAC) multiples of isoflurane in cats. Isoflurane MAC was determined using the tail-clamp method in eight domestic cats. Ten days later, the cats were anesthetized a second time with isoflurane at each of five MAC multiples administered in random order. Ventilation was controlled and, after a 20-min equilibration period at each MAC multiple of isoflurane, BIS data were collected for 5 min and the median BIS value calculated. Data from each isoflurane MAC multiple were compared using analysis of variance for repeated measures, and statistical significance was set at P < 0.05. The MAC of isoflurane (mean +/- 1 standard deviation) was 1.8% +/- 0.2%. BIS values at 0.5 MAC could not be recorded due to spontaneous movement in all eight cats. BIS values at 2.0 MAC were confounded by burst suppression in seven of the eight cats. Over the range of 0.8 to 1.5 MAC, BIS values decreased significantly with increasing end-tidal isoflurane concentrations. Mean (+/- 1 standard deviation) BIS measurements were 32 +/- 3 at 0.8 MAC, 20 +/- 4 at 1.0 MAC, and 5 +/- 3 at 1.5 MAC. Therefore, BIS values are inversely and linearly related to end-tidal isoflurane concentrations in anesthetized cats. However, the consistently low BIS values recorded in this study suggest that clinical BIS endpoints used to titrate anesthetic agents in humans may not be applicable to cats.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16089176

Source DB:  PubMed          Journal:  Comp Med        ISSN: 1532-0820            Impact factor:   0.982


  5 in total

1.  Paradoxical increase in the bispectral index during deep anesthesia in New Zealand white rabbits.

Authors:  Alexander Romanov; Rajinder-Singh Moon; Mei Wang; Shailendra Joshi
Journal:  J Am Assoc Lab Anim Sci       Date:  2014-01       Impact factor: 1.232

2.  Evaluation of the Cerebral State Index in Cats under Isoflurane Anaesthesia: Dose-Effect Relationship and Prediction of Clinical Signs.

Authors:  Joana R Sousa; Lénio Ribeiro; Aura Silva; David A Ferreira
Journal:  Vet Med Int       Date:  2014-01-30

3.  Clinical Use of a Multivariate Electroencephalogram (Narcotrend) for Assessment of Anesthetic Depth in Horses during Isoflurane-Xylazine Anesthesia.

Authors:  Julia Tünsmeyer; Klaus Hopster; Sabine B Kästner
Journal:  Front Vet Sci       Date:  2016-03-17

4.  Qualitative and Quantitative Characteristics of the Electroencephalogram in Normal Horses during Administration of Inhaled Anesthesia.

Authors:  D C Williams; R J Brosnan; D J Fletcher; M Aleman; T A Holliday; B Tharp; P H Kass; R A LeCouteur; E P Steffey
Journal:  J Vet Intern Med       Date:  2015-12-30       Impact factor: 3.333

5.  Effects of isoflurane, remifentanil and dexmedetomidine on selected EEG parameters derived from a Narcotrend Monitor before and after nociceptive stimulation at different MAC multiples in cats.

Authors:  Jonathan F Raue; Julia Tünsmeyer; Sabine B R Kästner
Journal:  BMC Vet Res       Date:  2020-09-14       Impact factor: 2.741

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.