Literature DB >> 16088358

Early results of a randomised trial comparing Prolene and VyproII-mesh in endoscopic extraperitoneal inguinal hernia repair (TEP) of recurrent unilateral hernias.

T Heikkinen1, S Wollert, J Osterberg, S Smedberg, S Bringman.   

Abstract

The purpose of this study was to compare a lightweight mesh to a standard polypropylene hernia mesh in endoscopic extraperitoneal hernioplasty in recurrent hernias. A total of 140 men with recurrent unilateral inguinal hernias were randomised to a totally extraperitoneal endoscopic hernioplasty (TEP) with Prolene or VyproII in a single-blinded multi-center trial. The randomisation and all data handling were performed through the Internet. 137 patients were operated as allocated. Follow-up was completed in 88% of the patients. The median operation times were 55 (24-125) min and 53.5 (21-123) min for the Prolene and VyproII groups, respectively. The meshes had comparable results in the surgeon's assessment of the handling of the mesh, return to work, return to daily activities, complications, postoperative pain and quality of life during the first 8 weeks of rehabilitation, except in General Health (GH) SF-36, where the VyproII-group had a significantly better score (P=0.045). The use of Prolene and VyproII-meshes in endoscopic repair of recurrent inguinal hernia seems to result in similar short-term outcomes and quality of life.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16088358     DOI: 10.1007/s10029-005-0026-6

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  23 in total

1.  Functional impairment and complaints following incisional hernia repair with different polypropylene meshes.

Authors:  G Welty; U Klinge; B Klosterhalfen; R Kasperk; V Schumpelick
Journal:  Hernia       Date:  2001-09       Impact factor: 4.739

Review 2.  Laparoscopic compared with open methods of groin hernia repair: systematic review of randomized controlled trials.

Authors: 
Journal:  Br J Surg       Date:  2000-07       Impact factor: 6.939

3.  Prospective study of chronic pain after groin hernia repair.

Authors:  T Callesen; K Bech; H Kehlet
Journal:  Br J Surg       Date:  1999-12       Impact factor: 6.939

4.  The Swedish SF-36 Health Survey III. Evaluation of criterion-based validity: results from normative population.

Authors:  M Sullivan; J Karlsson
Journal:  J Clin Epidemiol       Date:  1998-11       Impact factor: 6.437

5.  Functional and morphologic properties of a modified mesh for inguinal hernia repair.

Authors:  Karsten Junge; Uwe Klinge; Raphael Rosch; Bernd Klosterhalfen; Volker Schumpelick
Journal:  World J Surg       Date:  2002-09-26       Impact factor: 3.352

6.  Reoperation after recurrent groin hernia repair.

Authors:  S Haapaniemi; U Gunnarsson; P Nordin; E Nilsson
Journal:  Ann Surg       Date:  2001-07       Impact factor: 12.969

7.  Laparoscopic inguinal hernia repair: lessons learned after 1224 consecutive cases.

Authors:  B Ramshaw; F W Shuler; H B Jones; T D Duncan; J White; R Wilson; G W Lucas; E M Mason
Journal:  Surg Endosc       Date:  2001-01       Impact factor: 4.584

8.  Open mesh versus laparoscopic mesh repair of inguinal hernia.

Authors:  Leigh Neumayer; Anita Giobbie-Hurder; Olga Jonasson; Robert Fitzgibbons; Dorothy Dunlop; James Gibbs; Domenic Reda; William Henderson
Journal:  N Engl J Med       Date:  2004-04-25       Impact factor: 91.245

Review 9.  A review of chronic pain after inguinal herniorrhaphy.

Authors:  Amudha S Poobalan; Julie Bruce; W Cairns S Smith; Peter M King; Zygmunt H Krukowski; W Alastair Chambers
Journal:  Clin J Pain       Date:  2003 Jan-Feb       Impact factor: 3.442

10.  Chronic pain after laparoscopic and open mesh repair of groin hernia.

Authors:  S Kumar; R G Wilson; S J Nixon; I M C Macintyre
Journal:  Br J Surg       Date:  2002-11       Impact factor: 6.939

View more
  29 in total

Review 1.  Inguinal hernia repair: current surgical techniques.

Authors:  R Bittner; J Schwarz
Journal:  Langenbecks Arch Surg       Date:  2011-11-25       Impact factor: 3.445

Review 2.  Improving outcomes in hernia repair by the use of light meshes--a comparison of different implant constructions based on a critical appraisal of the literature.

Authors:  Dirk Weyhe; Orlin Belyaev; Christophe Müller; Kirsten Meurer; Karl-Heinz Bauer; Georgios Papapostolou; Waldemar Uhl
Journal:  World J Surg       Date:  2007-01       Impact factor: 3.352

Review 3.  Lightweight versus heavyweight mesh in laparoscopic inguinal hernia repair: a meta-analysis.

Authors:  Andrew Currie; Helen Andrew; Alfredo Tonsi; Paul R Hurley; Sanjay Taribagil
Journal:  Surg Endosc       Date:  2012-02-07       Impact factor: 4.584

4.  Lightweight mesh versus heavyweight mesh for laparo-endoscopic inguinal hernia repair: a systematic review and meta-analysis.

Authors:  F Wu; X Zhang; Y Liu; D Cao; Y Yu; Y Ma
Journal:  Hernia       Date:  2019-07-31       Impact factor: 4.739

Review 5.  Convalescence after laparoscopic inguinal hernia repair: a qualitative systematic review.

Authors:  Mette Astrup Tolver; Jacob Rosenberg; Thue Bisgaard
Journal:  Surg Endosc       Date:  2016-04-08       Impact factor: 4.584

6.  Lightweight mesh and noninvasive fixation: an effective concept for prevention of chronic pain with laparoscopic hernia repair (TAPP).

Authors:  Reinhard Bittner; Eliza Gmähle; Björn Gmähle; Jochen Schwarz; Eske Aasvang; Henrik Kehlet
Journal:  Surg Endosc       Date:  2010-06-05       Impact factor: 4.584

7.  Comparison of a lightweight polypropylene mesh (Optilene® LP) and a large-pore knitted PTFE mesh (GORE® INFINIT® mesh)--Biocompatibility in a standardized endoscopic extraperitoneal hernia model.

Authors:  Dietmar A Jacob; Christine Schug-Pass; Florian Sommerer; Andrea Tannapfel; Hans Lippert; Ferdinand Köckerling
Journal:  Langenbecks Arch Surg       Date:  2011-10-12       Impact factor: 3.445

8.  Early postoperative and one year results of a randomized controlled trial comparing the impact of extralight titanized polypropylene mesh and traditional heavyweight polypropylene mesh on pain and seroma production in laparoscopic hernia repair (TAPP).

Authors:  R Bittner; C-G Schmedt; B J Leibl; J Schwarz
Journal:  World J Surg       Date:  2011-08       Impact factor: 3.352

Review 9.  Causes of recurrence in laparoscopic inguinal hernia repair.

Authors:  Manjunath Siddaiah-Subramanya; Darius Ashrafi; Breda Memon; Muhammed Ashraf Memon
Journal:  Hernia       Date:  2018-08-25       Impact factor: 4.739

10.  Comparison of recurrence with lightweight composite polypropylene mesh and heavyweight mesh in laparoscopic totally extraperitoneal inguinal hernia repair: an audit of 1,232 repairs.

Authors:  D Akolekar; S Kumar; L R Khan; A C de Beaux; S J Nixon
Journal:  Hernia       Date:  2007-09-13       Impact factor: 4.739

View more