Thawing of frozen calcaneus bone specimens has no effect on the bone mineral density using dual energy x-ray absorptiometry: a study in rabbits and humans.

Guy Trudel1, Yoichi Koike, Laurent Dinh, Hans K Uhthoff.   

Abstract

The purpose of this paper is to study whether the deep freezing of bone and later thawing affects the bone mineral density (BMD) measurement. We used 56 calcanei from 28 adult female New Zealand white rabbits and 102 human calcanei from 51 donors post-mortem (27 men and 24 women, age 30-89). Dual energy x-ray absorptiometry evaluated BMD of the frozen specimen and of the thawed specimen. A main analysis compared BMD of each specimen in the frozen and thawed states. The mean BMD of 224 areas of frozen rabbits' calcanei was 0.31 +/- 0.08 g cm(-2) (95% confidence interval (CI) from 0.30 to 0.32 g cm(-2)) while the mean BMD of thawed rabbits' calcanei was 0.31 +/- 0.08 g cm(-2) (95% CI from 0.30 to 0.32 g cm(-2); paired t-test p > 0.01). The mean BMD of 306 areas of frozen human calcaneus was 0.73 +/- 0.22 g cm(-2) (95% CI from 0.70 to 0.76 g cm(-2)) while the mean BMD of thawed human calcaneus was 0.73 +/- 0.22 g cm(-2) (95% CI from 0.70 to 0.76 g cm(-2); p > 0.01). For both the rabbit and the human calcanei, a Bland-Altman analysis showed a mean difference between the BMD in the frozen and thawed states of 0.00 (limits of agreement, rabbit: -0.07 to 0.08 g cm(-2), human: -0.16 to 0.21 g cm(-2)). A high correlation was observed between calcaneus BMD in the frozen and thawed states (r = 0.94, 0.97, 0.92 and 0.99 respectively in all rabbit calcanei, all human calcanei, immobilized rabbit calcanei and osteopenic human calcanei, all p < 0.01). Bone mineral density is not affected by deep freezing and later thawing of the specimen. Therefore, the specimens need not be thawed to obtain valid and precise BMD measurement. These results are relevant to general musculoskeletal as well as osteoporosis research where the specimens undergo multiple tests in series.

Entities:  

Mesh:

Year:  2005        PMID: 16088067     DOI: 10.1088/0967-3334/26/5/015

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  2 in total

1.  2008 Otto Aufranc Award: component design and technique affect cement penetration in hip resurfacing.

Authors:  Paul E Beaulé; Wadih Y Matar; Philippe Poitras; Kevin Smit; Olivier May
Journal:  Clin Orthop Relat Res       Date:  2008-10-16       Impact factor: 4.176

2.  A novel method for intraoperative osseomechanical strength measurements: a biomechanical ex vivo evaluation on proximal femora.

Authors:  Alexander Maslaris; Olaf Brinkmann; Frank Layher; Georg Matziolis; Matthias Bungartz
Journal:  Arch Orthop Trauma Surg       Date:  2019-11-06       Impact factor: 3.067

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.