Literature DB >> 16077232

Calculations of neutron dose equivalent exposures from range-modulated proton therapy beams.

Jerimy C Polf1, Wayne D Newhauser.   

Abstract

Passive beam spreading techniques have been used for most proton therapy treatments worldwide. This delivery method employs static scattering foils to spread the beam laterally and a range modulating wheel or ridge filter to spread the high dose region in depth to provide a uniform radiation dose to the treatment volume. Neutrons produced by interactions of the treatment beam with nozzle components, such as the range modulation wheel, can account for a large portion of the secondary dose delivered to healthy tissue outside the treatment volume. Despite this fact, little is known about the effects of range modulation on the secondary neutron exposures around passively scattered proton treatment nozzles. In this work, the neutron dose equivalent spectra per incident proton (H(E)/p) and total neutron dose equivalent per therapeutic absorbed dose (H/D) were studied using Monte Carlo techniques for various values of range modulation at 54 locations around a passive scattering proton therapy treatment nozzle. As the range modulator wheel step thickness increased from 1.0 to 11.5 cm, the peak values of H(E)/p decreased from approximately 1 x 10(-17) mSv Gy(-1) to approximately 2 x 10(-18) mSv Gy(-1) at 50 cm from isocentre along the beam's central axis. In general, H/D increased with increasing range modulation at all locations studied, and the maximum H/D exposures shifted away from isocentre.

Mesh:

Substances:

Year:  2005        PMID: 16077232     DOI: 10.1088/0031-9155/50/16/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  27 in total

1.  An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle.

Authors:  Gabriel O Sawakuchi; Dragan Mirkovic; Luis A Perles; Narayan Sahoo; X Ron Zhu; George Ciangaru; Kazumichi Suzuki; Michael T Gillin; Radhe Mohan; Uwe Titt
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  An analytic model of neutron ambient dose equivalent and equivalent dose for proton radiotherapy.

Authors:  Rui Zhang; Angélica Pérez-Andújar; Jonas D Fontenot; Phillip J Taddei; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

3.  Assessment of out-of-field absorbed dose and equivalent dose in proton fields.

Authors:  Ben Clasie; Andrew Wroe; Hanne Kooy; Nicolas Depauw; Jay Flanz; Harald Paganetti; Anatoly Rosenfeld
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

4.  Monte Carlo and analytical model predictions of leakage neutron exposures from passively scattered proton therapy.

Authors:  Angélica Pérez-Andújar; Rui Zhang; Wayne Newhauser
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

5.  Fan-beam intensity modulated proton therapy.

Authors:  Patrick Hill; David Westerly; Thomas Mackie
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

Review 6.  Assessment of the risk for developing a second malignancy from scattered and secondary radiation in radiation therapy.

Authors:  Harald Paganetti
Journal:  Health Phys       Date:  2012-11       Impact factor: 1.316

7.  Neutron production from beam-modifying devices in a modern double scattering proton therapy beam delivery system.

Authors:  Angélica Pérez-Andújar; Wayne D Newhauser; Paul M Deluca
Journal:  Phys Med Biol       Date:  2009-01-16       Impact factor: 3.609

8.  Reduction of the secondary neutron dose in passively scattered proton radiotherapy, using an optimized pre-collimator/collimator.

Authors:  David J Brenner; Carl D Elliston; Eric J Hall; Harald Paganetti
Journal:  Phys Med Biol       Date:  2009-09-24       Impact factor: 3.609

9.  Assessment of the accuracy of an MCNPX-based Monte Carlo simulation model for predicting three-dimensional absorbed dose distributions.

Authors:  U Titt; N Sahoo; X Ding; Y Zheng; W D Newhauser; X R Zhu; J C Polf; M T Gillin; R Mohan
Journal:  Phys Med Biol       Date:  2008-07-31       Impact factor: 3.609

10.  Monte Carlo simulation of the neutron spectral fluence and dose equivalent for use in shielding a proton therapy vault.

Authors:  Yuanshui Zheng; Wayne Newhauser; Eric Klein; Daniel Low
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

View more