A technique for respiratory-gated radiotherapy treatment verification with an EPID in cine mode.

Ross I Berbeco1, Toni Neicu, Eike Rietzel, George T Y Chen, Steve B Jiang.   

Abstract

Respiratory gating based on external surrogates is performed in many clinics. We have developed a new technique for treatment verification using an electronic portal imaging device (EPID) in cine mode for gated 3D conformal therapy. Implanted radiopaque fiducial markers inside or near the target are required for this technique. The markers are contoured on the planning CT set, enabling us to create digitally reconstructed radiographs (DRRs) for each treatment beam. During the treatment, a sequence of EPID images can be acquired without disrupting the treatment. Implanted markers are visualized in the images and their positions in the beam's eye view are calculated off-line and compared to the reference position by matching the field apertures in corresponding EPID and DRR images. The precision of the patient set-up, the placement of the beam-gating window, as well as the residual tumour motion can be assessed for each treatment fraction. This technique has been demonstrated with a case study patient, who had three markers implanted in his liver. For this patient, the intra-fractional variation of all marker positions in the gating window had a 95% range of 4.8 mm in the SI direction (the primary axis of motion). This was about the same (5 mm) as the residual motion considered in the planning process. The inter-fractional variation of the daily mean positions of the markers, which indicates the uncertainty in the set-up procedure, was within +8.3 mm/-4.5 mm (95% range) in the SI direction for this case.

Entities:  

Mesh:

Year:  2005        PMID: 16077220     DOI: 10.1088/0031-9155/50/16/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  Quantification of the thorax-to-abdomen breathing ratio for breathing motion modeling.

Authors:  Benjamin M White; Tianyu Zhao; James Lamb; Jeffrey D Bradley; Daniel A Low
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

2.  Investigation into the feasibility of using PRESAGE/optical-CT dosimetry for the verification of gating treatments.

Authors:  Samuel L Brady; William E Brown; Corey G Clift; Sua Yoo; Mark Oldham
Journal:  Phys Med Biol       Date:  2010-03-26       Impact factor: 3.609

3.  Registration of clinical volumes to beams-eye-view images for real-time tracking.

Authors:  Jonathan H Bryant; Joerg Rottmann; John H Lewis; Pankaj Mishra; Paul J Keall; Ross I Berbeco
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

4.  Asymmetric margin setting at the cranial and caudal sides in respiratory gated and non-gated stereotactic body radiotherapy for lung cancer.

Authors:  Yoshihiro Ueda; Shingo Oohira; Masaru Isono; Masayoshi Miyazaki; Teruki Teshima
Journal:  Br J Radiol       Date:  2015-12-23       Impact factor: 3.039

5.  Automated target tracking in kilovoltage images using dynamic templates of fiducial marker clusters.

Authors:  Warren G Campbell; Moyed Miften; Bernard L Jones
Journal:  Med Phys       Date:  2017-02       Impact factor: 4.071

6.  Tumor trailing strategy for intensity-modulated radiation therapy of moving targets.

Authors:  Alexei Trofimov; Christian Vrancic; Timothy C Y Chan; Gregory C Sharp; Thomas Bortfeld
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

7.  Planning target volume assessment in lung tumors during 3D conformal radiotherapy by means of an aSi electronic portal imaging device in cine mode.

Authors:  R Caivano; S Clemente; A Fiorentino; C Chiumento; P Pedicini; G Califano; M Cozzolino; V Fusco
Journal:  Clin Transl Oncol       Date:  2013-01-24       Impact factor: 3.405

8.  On the accuracy of a moving average algorithm for target tracking during radiation therapy treatment delivery.

Authors:  Rohini George; Yelin Suh; Martin Murphy; Jeffrey Williamson; Elizabeth Weiss; Paul Keall
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

9.  Analysis of the optimum internal margin for respiratory-gated radiotherapy using end-expiratory phase assessments using a motion phantom.

Authors:  Yuji Yaegashi; Kunihiko Tateoka; Takuya Nakazawa; Kazunori Fujimoto; Katsumi Shima; Junji Suzuki; Akihiro Nakata; Yuichi Saito; Tadanori Abe; Koichi Sakata; Masato Hareyama
Journal:  J Appl Clin Med Phys       Date:  2012-03-08       Impact factor: 2.102

10.  Evaluation of the need for simultaneous orthogonal gated setup imaging.

Authors:  Ross I Berbeco; Seiko Nishioka; Hiroki Shirato
Journal:  J Appl Clin Med Phys       Date:  2010-04-19       Impact factor: 2.102