Use of a single silastic chest drain following thoracotomy: initial evaluation.

Nand K Kejriwal1, Mark A J Newman.   

Abstract

BACKGROUND: It is standard practice to use multiple large bore semi-rigid chest tubes to drain the pleural cavity following thoracic procedures. These can cause pain and discomfort at the insertion site.
METHODS: We describe our experience with the use of a single small silastic drain following thoracotomy. From November 2001 to November 2003, size 19-F silastic chest tubes (Blake drains) were used for drainage of the pleural cavity in 37 patients at our institution. The patients ranged in age from 18 to 81 years (mean 65). The operations included 22 lobectomies, two bilobectomies, 10 wedge resections, and three other procedures.
RESULTS: Total drainage in each patient ranged from 420 to 5440 mL (mean 1387 mL). Tubes were left in place for an average of 4.3 days (range 1-12). The average postoperative length of stay was 7.6 days (range 3-44, median 5). Three patients required insertion of an additional tube for dislodgement, persistent air leak, and bronchopleural fistula, respectively. These complications occurred among the first 15 patients in the present series. None of the patients had persistent pleural effusion. Subjectively, these tubes were more comfortable for the patients and were easier to remove.
SUMMARY: The use of a single, small silastic chest drains following thoracotomy may be safe and effective in draining both fluid and air, though an additional tube may be necessary for persistent leaks.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16076338     DOI: 10.1111/j.1445-2197.2005.03479.x

Source DB:  PubMed          Journal:  ANZ J Surg        ISSN: 1445-1433            Impact factor:   1.872


  4 in total

1.  The Redax® Coaxial Drain in pulmonary lobectomy: a study of efficacy.

Authors:  Ottavio Rena; Sara Parini; Esther Papalia; Fabio Massera; Davide Turello; Guido Baietto; Caterina Casadio
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

2.  Novel Split Chest Tube Improves Post-Surgical Thoracic Drainage.

Authors:  Albert H Olivencia-Yurvati; Brandon H Cherry; Hunaid A Gurji; Daniel W White; J Tyler Newton; Gary F Scott; Besim Hoxha; Terence Gourlay; Robert T Mallet
Journal:  J Clin Exp Cardiolog       Date:  2014

3.  Application of the coaxial smart drain in patients with a large air leak following anatomic lung resection: a prospective multicenter phase II analysis of efficacy and safety.

Authors:  Francesco Guerrera; Pier Luigi Filosso; Cecilia Pompili; Stefania Olivetti; Matteo Roffinella; Andrea Imperatori; Alessandro Brunelli
Journal:  J Vis Surg       Date:  2018-01-29

4.  Liver injury secondary to chest tube placement: a case report of conservative management and review of literature.

Authors:  Badr Serji; Houda Mirali; Mohammed Chablou; Imane Kamaoui; Tijani El Harroudi
Journal:  Clin Case Rep       Date:  2017-11-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.