Literature DB >> 16075536

Continuous focus tracking for real-time optical coherence tomography.

Michael J Cobb1, Xiumei Liu, Xingde Li.   

Abstract

We report an approach to achieving continuous focus tracking and a depth-independent transverse resolution for real-time optical coherence tomography (OCT) imaging. Continuous real-time focus tracking is permitted by use of a lateral-priority image acquisition sequence in which the depth-scanning rate is equivalent to the imaging frame rate. Real-time OCT imaging with continuous focus tracking is performed at 1 frame/s by reciprocal translation of a rapid lateral-scanning miniature imaging probe (e.g., an endoscope). The optical path length in the reference arm is scanned synchronously to ensure that the coherence gate coincides with the imaging beam focus. The image quality improvement is experimentally demonstrated by imaging a tissue phantom embedded with polystyrene microspheres and rabbit esophageal tissues.

Entities:  

Mesh:

Year:  2005        PMID: 16075536     DOI: 10.1364/ol.30.001680

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  9 in total

1.  Increased illumination uniformity and reduced photodamage offered by the Lissajous scanning in fiber-optic two-photon endomicroscopy.

Authors:  Wenxuan Liang; Kartikeya Murari; Yuying Zhang; Yongping Chen; Ming-Jun Li; Xingde Li
Journal:  J Biomed Opt       Date:  2012-02       Impact factor: 3.170

2.  Dynamic focus-tracking MEMS scanning micromirror with low actuation voltages for endoscopic imaging.

Authors:  Matthew Strathman; Yunbo Liu; Xingde Li; Lih Y Lin
Journal:  Opt Express       Date:  2013-10-07       Impact factor: 3.894

3.  Correction of circumferential and longitudinal motion distortion in high-speed catheter/endoscope-based optical coherence tomography.

Authors:  Tan Huu Nguyen; Osman Oguz Ahsen; Kaicheng Liang; Jason Zhang; Hiroshi Mashimo; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2020-12-09       Impact factor: 3.732

4.  Lateral resolution improvement of oversampled OCT images using Capon estimation of weighted subvolume contribution.

Authors:  Evgenia Bousi; Ioanna Zouvani; Costas Pitris
Journal:  Biomed Opt Express       Date:  2017-02-06       Impact factor: 3.732

5.  Endoscopic optical coherence tomography: technologies and clinical applications [Invited].

Authors:  Michalina J Gora; Melissa J Suter; Guillermo J Tearney; Xingde Li
Journal:  Biomed Opt Express       Date:  2017-04-07       Impact factor: 3.732

6.  Integrated multimodal endomicroscopy platform for simultaneous en face optical coherence and two-photon fluorescence imaging.

Authors:  Jiefeng Xi; Yongping Chen; Yuying Zhang; Kartikeya Murari; Ming-Jun Li; Xingde Li
Journal:  Opt Lett       Date:  2012-02-01       Impact factor: 3.776

7.  Minimizing OCT quantification error via a surface-tracking imaging probe.

Authors:  Hyeon-Cheol Park; Ang Li; Honghua Guan; Chetan Bettegowda; Kaisorn Chaichana; Alfredo Quiñones-Hinojosa; Xingde Li
Journal:  Biomed Opt Express       Date:  2021-06-10       Impact factor: 3.562

8.  Digital focusing of OCT images based on scalar diffraction theory and information entropy.

Authors:  Guozhong Liu; Zhongwei Zhi; Ruikang K Wang
Journal:  Biomed Opt Express       Date:  2012-10-10       Impact factor: 3.732

9.  A forward-imaging needle-type OCT probe for image guided stereotactic procedures.

Authors:  Chia-Pin Liang; Jeremiah Wierwille; Thais Moreira; Gary Schwartzbauer; M Samir Jafri; Cha-Min Tang; Yu Chen
Journal:  Opt Express       Date:  2011-12-19       Impact factor: 3.894

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.