Literature DB >> 16051439

The substructure of immunoglobulin G resolved to 25 kDa using amplitude modulation AFM in air.

Neil H Thomson1.   

Abstract

Amplitude modulation (or tapping-mode) atomic force microscopy (AM AFM or TM AFM) in air can reveal sub-molecular details of isolated multi-subunit proteins, such as immunoglobulin G (IgG) antibodies, on atomically flat support surfaces such as mica [A. San Paulo, R. Garcia, Biophys. J. 78(3) (2000) 1599]. This is achieved by controlling the microscope imaging parameters (e.g. cantilever drive frequency and set-point amplitude) to keep the AFM tip predominantly in the attractive force regime. Under these conditions, the 50 kDa F(c) and F(ab) subunits can be resolved when the molecule has the appropriate orientation on the surface. The presence of a water layer on hydrophilic mica is an important factor affecting imaging contrast, a consequence of capillary neck formation between tip and surface [L. Zitzler, S. Herminghaus, F. Mugele, Phys. Rev. B 66(15) (2002) 155436]. Desiccation of samples to remove surface bound water layers can yield reproducible imaging of the IgG substructure [N.H. Thomson, J. Microsc. (Oxford) 217(3) (2004) 193]. This approach has also given higher resolution than previously achieved, down to about 25 kDa, and these data are detailed here. These subdomains are formed as two immunoglobulin folds from the light and heavy peptide chains of the IgG crossover. This result has been validated by comparing the AFM images with X-ray crystallography data from the protein data bank. These data show that the AFM can obtain 25 kDa resolution on isolated protein molecules with commercially available silicon tips, but, as expected for a local probe technique, resolution is highly dependent on the macromolecular orientation on the support surface.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16051439     DOI: 10.1016/j.ultramic.2005.06.024

Source DB:  PubMed          Journal:  Ultramicroscopy        ISSN: 0304-3991            Impact factor:   2.689


  5 in total

1.  Nanoscale probing reveals that reduced stiffness of clots from fibrinogen lacking 42 N-terminal Bbeta-chain residues is due to the formation of abnormal oligomers.

Authors:  Radwa H Abou-Saleh; Simon D Connell; Robert Harrand; Ramzi A Ajjan; Michael W Mosesson; D Alastair M Smith; Peter J Grant; Robert A S Ariëns
Journal:  Biophys J       Date:  2009-03-18       Impact factor: 4.033

2.  Atomic force microscopy captures folded ribosome bound nascent chains.

Authors:  Anna Loksztejn; Zackary Scholl; Piotr E Marszalek
Journal:  Chem Commun (Camb)       Date:  2012-10-11       Impact factor: 6.222

3.  Immunoactive two-dimensional self-assembly of monoclonal antibodies in aqueous solution revealed by atomic force microscopy.

Authors:  Shinichiro Ido; Hirokazu Kimiya; Kei Kobayashi; Hiroaki Kominami; Kazumi Matsushige; Hirofumi Yamada
Journal:  Nat Mater       Date:  2014-01-19       Impact factor: 43.841

4.  Formation of multimeric antibodies for self-delivery of active monomers.

Authors:  Yaron Dekel; Yossy Machluf; Tal Gefen; Gennady Eidelshtein; Alexander Kotlyar; Yaron Bram; Ehud Shahar; Farah Reslane; Elina Aizenshtein; Jacob Pitcovski
Journal:  Drug Deliv       Date:  2017-11       Impact factor: 6.419

5.  Nano-visualization of oriented-immobilized IgGs on immunosensors by high-speed atomic force microscopy.

Authors:  Masumi Iijima; Masaharu Somiya; Nobuo Yoshimoto; Tomoaki Niimi; Shun'ichi Kuroda
Journal:  Sci Rep       Date:  2012-11-09       Impact factor: 4.379

  5 in total