Literature DB >> 16049239

Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral component.

R Raman1, R P Kamath, A Parikh, P D Angus.   

Abstract

We report the clinical and radiological outcome of 86 revisions of cemented hip arthroplasties using JRI-Furlong hydroxyapatite-ceramic-coated acetabular and femoral components. The acetabular component was revised in 62 hips and the femoral component in all hips. The mean follow-up was 12.6 years and no patient was lost to follow-up. The mean age of the patients was 71.2 years. The mean Harris hip and Oxford scores were 82 (59 to 96) and 23.4 (14 to 40), respectively. The mean Charnley modification of the Merle d'Aubigné and Postel score was 5 (3 to 6) for pain, 4.9 (3 to 6) for movement and 4.4 (3 to 6) for mobility. Migration of the acetabular component was seen in two hips and the mean acetabular inclination was 42.6 degrees. The mean linear polyethylene wear was 0.05 mm/year. The mean subsidence of the femoral component was 1.9 mm and stress shielding was seen in 23 (28%) with bony ingrowth in 76 (94%). Heterotopic ossification was seen in 12 hips (15%). There were three re-revisions, two for deep sepsis and one for recurrent dislocation and there were no re-revisions for aseptic loosening. The mean EuroQol EQ-5D description scores and health thermometer scores were 0.69 (0.51 to 0.89) and 79 (54 to 95), respectively. With an end-point of definite or probable loosening, the probability of survival at 12 years was 93.9% and 95.6% for the acetabular and femoral components, respectively. Overall survival at 12 years, with removal or further revision of either component for any reason as the end-point, was 92.3%. Our study supports the continued use of this arthroplasty and documents the durability of hydroxyapatite-ceramic-coated components.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16049239     DOI: 10.1302/0301-620X.87B8.16161

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  6 in total

1.  Mechanical, in vitro antimicrobial, and biological properties of plasma-sprayed silver-doped hydroxyapatite coating.

Authors:  Mangal Roy; Gary A Fielding; Haluk Beyenal; Amit Bandyopadhyay; Susmita Bose
Journal:  ACS Appl Mater Interfaces       Date:  2012-02-28       Impact factor: 9.229

2.  Femoral revision with an extensively hydroxyapatite-coated femoral component.

Authors:  Lawrence V Gulotta; Andreas Baldini; Kristin Foote; Stephen Lyman; Bryan J Nestor
Journal:  HSS J       Date:  2007-12-01

3.  Bone remodeling after a mean of 10 years in diaphyseal cortical defects repaired with femoral revision using bypass fixation of extensively porous-coated stems with high stiffness.

Authors:  Kiyokazu Fukui; Ayumi Kaneuji; Tanzo Sugimori; Toru Ichiseki; Tadami Matsumoto
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-01-04

4.  Proximal Femoral Bone Regeneration After an Uncemented Hydroxyapatite-coated Long-stem in Revision Hip Surgery.

Authors:  José Cordero-Ampuero; Eduardo Garcia-Rey; Eduardo Garcia-Cimbrelo
Journal:  Open Orthop J       Date:  2018-03-30

5.  Large femoral bone loss after hip revision using the uncemented proximally porous-coated Bi-Metric prosthesis: 22 hips followed for a mean of 6 years.

Authors:  Per Y Adolphson; Mats O F Salemyr; Olof G Sköldenberg; Henrik S G Bodén
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

6.  Results and Patient Reported Outcome Measures (PROMs) after One-Stage Revision for Periprosthetic Joint Infection of the Hip: A Single-centre Retrospective Study.

Authors:  Jesse W P Kuiper; Christine M E Rustenburg; Jore H Willems; Steven J Verberne; Edgar J G Peters; Rachid Saouti
Journal:  J Bone Jt Infect       Date:  2018-07-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.