Hydroxyapatite-ceramic-coated femoral stems in revision hip surgery.

S P Trikha1, S Singh, O W Raynham, J C Lewis, P A Mitchell, A J Edge.   

Abstract

We describe the clinical and radiological results of 120 consecutive revision hip replacements in 107 patients, using the JRI Furlong hydroxyapatite-ceramic-coated femoral component. The mean age of the patients at operation was 71 years (36 to 92) and the mean length of follow-up 8.0 years (5.0 to 12.4). We included patients on whom previous revision hip surgery had taken place. The patients were independently reviewed and scored using the Harris hip score, the Western Ontario and McMaster Universities osteoarthritis index (WOMAC) and the Charnley modification of the Merle d'Aubigné and Postel score. Radiographs were assessed by three reviewers for the formation of new bone, osteolysis, osseointegration and radiolucent lines in each Gruen zone. The mean Harris hip score was 85.8 (42 to 100) at the latest post-operative review. The mean WOMAC and Merle d'Aubigné and Postel scores were 34.5 and 14.8, respectively. The mean visual analogue score for pain (possible range 0 to 10) was 1.2 overall, but 0.5 specifically for mid-thigh pain. There were no revisions of the femoral component for aseptic loosening. There were four re-revisions, three for infection and one for recurrent dislocation. Radiological review of all the femoral components, including the four re-revisions showed stable bony ingrowth and no new radiolucent lines in any zone. Using revision or impending revision for aseptic loosening as an end-point, the cumulative survival of the femoral component at ten years was 100% (95% confidence interval 94 to 100). We present excellent medium- to long-term clinical, radiological and survivorship results with the fully hydroxyapatite-ceramic-coated femoral component in revision hip surgery.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16049238     DOI: 10.1302/0301-620X.87B8.16053

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  6 in total

1.  Mechanical, in vitro antimicrobial, and biological properties of plasma-sprayed silver-doped hydroxyapatite coating.

Authors:  Mangal Roy; Gary A Fielding; Haluk Beyenal; Amit Bandyopadhyay; Susmita Bose
Journal:  ACS Appl Mater Interfaces       Date:  2012-02-28       Impact factor: 9.229

2.  Femoral revision with an extensively hydroxyapatite-coated femoral component.

Authors:  Lawrence V Gulotta; Andreas Baldini; Kristin Foote; Stephen Lyman; Bryan J Nestor
Journal:  HSS J       Date:  2007-12-01

3.  Fixation of hydroxyapatite-coated revision implants is improved by the surgical technique of cracking the sclerotic bone rim.

Authors:  Brian Elmengaard; Joan E Bechtold; Xinqian Chen; Kjeld Søballe
Journal:  J Orthop Res       Date:  2009-08       Impact factor: 3.494

4.  Inflammatory cell response to ultra-thin amorphous and crystalline hydroxyapatite surfaces.

Authors:  Louise Rydén; Omar Omar; Anna Johansson; Ryo Jimbo; Anders Palmquist; Peter Thomsen
Journal:  J Mater Sci Mater Med       Date:  2016-11-28       Impact factor: 3.896

5.  Proximal Femoral Bone Regeneration After an Uncemented Hydroxyapatite-coated Long-stem in Revision Hip Surgery.

Authors:  José Cordero-Ampuero; Eduardo Garcia-Rey; Eduardo Garcia-Cimbrelo
Journal:  Open Orthop J       Date:  2018-03-30

6.  Large femoral bone loss after hip revision using the uncemented proximally porous-coated Bi-Metric prosthesis: 22 hips followed for a mean of 6 years.

Authors:  Per Y Adolphson; Mats O F Salemyr; Olof G Sköldenberg; Henrik S G Bodén
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717