PURPOSE: To compare differences in the applicability and incidence of postoperative adverse events among stent-grafts used for repair of infrarenal aortic aneurysms. METHODS: An analysis of 6787 patients from the EUROSTAR Registry database was conducted to compare aneurysm morphological features, patient characteristics, and postoperative events for the AneuRx, EVT/Ancure, Excluder, Stentor, Talent, and Zenith devices versus the Vanguard device (control) and each other. Annual incidence rates of complications were determined, and risks were compared using the Cox proportional hazards analysis. RESULTS: The annual incidence rates were: device-related endoleak (types I and III) 6% (range 4%-10%), type II endoleak 5% (range 0.3%-11%), migration 3% (range 0.5%-5%), kinking 2% (range 1%-5%), occlusion 3% (range 1%-5%), rupture 0.5% (range 0%-1%), and all-cause mortality 7% (range 5%-8%). After adjustment for factors influencing outcome, AneuRx, Excluder, Talent, and Zenith devices were associated with a lower risk of migration, kinking, occlusion, and secondary intervention compared to the Vanguard device. Significant increased risk for conversion (EVT/Ancure) and reduced risk of aneurysm rupture (AneuRx and Zenith) and all-cause mortality (Excluder) were found compared to the Vanguard device. CONCLUSIONS: Significant differences exist between stent-grafts of different labels in terms of applicability and complications during intermediate to long-term follow-up. Since each stent-graft has its drawbacks, no single label can be identified as the best. It is reassuring that developments in stent-grafts indeed result in better performance than the early stent-grafts. However, a single device incorporating all the perceived improvements should still be pursued.
PURPOSE: To compare differences in the applicability and incidence of postoperative adverse events among stent-grafts used for repair of infrarenal aortic aneurysms. METHODS: An analysis of 6787 patients from the EUROSTAR Registry database was conducted to compare aneurysm morphological features, patient characteristics, and postoperative events for the AneuRx, EVT/Ancure, Excluder, Stentor, Talent, and Zenith devices versus the Vanguard device (control) and each other. Annual incidence rates of complications were determined, and risks were compared using the Cox proportional hazards analysis. RESULTS: The annual incidence rates were: device-related endoleak (types I and III) 6% (range 4%-10%), type II endoleak 5% (range 0.3%-11%), migration 3% (range 0.5%-5%), kinking 2% (range 1%-5%), occlusion 3% (range 1%-5%), rupture 0.5% (range 0%-1%), and all-cause mortality 7% (range 5%-8%). After adjustment for factors influencing outcome, AneuRx, Excluder, Talent, and Zenith devices were associated with a lower risk of migration, kinking, occlusion, and secondary intervention compared to the Vanguard device. Significant increased risk for conversion (EVT/Ancure) and reduced risk of aneurysm rupture (AneuRx and Zenith) and all-cause mortality (Excluder) were found compared to the Vanguard device. CONCLUSIONS: Significant differences exist between stent-grafts of different labels in terms of applicability and complications during intermediate to long-term follow-up. Since each stent-graft has its drawbacks, no single label can be identified as the best. It is reassuring that developments in stent-grafts indeed result in better performance than the early stent-grafts. However, a single device incorporating all the perceived improvements should still be pursued.
Authors: Kristina A Giles; Bruce E Landon; Philip Cotterill; A James O'Malley; Frank B Pomposelli; Marc L Schermerhorn Journal: J Vasc Surg Date: 2010-10-27 Impact factor: 4.268
Authors: Lucas W Buchanan; S William Stavropoulos; Joshua B Resnick; Jeffrey Solomon Journal: Semin Intervent Radiol Date: 2009-03 Impact factor: 1.513
Authors: Jade S Hiramoto; Catherine K Chang; Linda M Reilly; Darren B Schneider; Joseph H Rapp; Timothy A M Chuter Journal: J Vasc Surg Date: 2009-02-23 Impact factor: 4.268
Authors: Robert W Chang; Philip Goodney; Lue-Yen Tucker; Steven Okuhn; Hong Hua; Ann Rhoades; Nayan Sivamurthy; Bradley Hill Journal: J Vasc Surg Date: 2013-05-14 Impact factor: 4.268
Authors: Konrad Salata; Muzammil Syed; Mohamad A Hussain; Charles de Mestral; Elisa Greco; Muhammad Mamdani; Jack V Tu; Thomas L Forbes; Deepak L Bhatt; Subodh Verma; Mohammed Al-Omran Journal: J Am Heart Assoc Date: 2018-10-02 Impact factor: 5.501