BACKGROUND AND
OBJECTIVE: As the number of patients with implantable cardiac devices escalates, inadvertent electromagnetic interference (EMI) by electrosurgery carries increasing concern for patient safety. Given the trend for dermatologic care delivery by nonphysician providers, supervising physicians must carefully consider the adequacy of perioperative evaluation in elective or cosmetic settings. Rapidly evolving technology also calls into question potential EMI of new therapeutic modalities (radiofrequency resurfacing, electrochemotherapy, and endovenous ablation). The most recently published recommendations (1998) for care of dermatologic patients with cardiac devices do not differ significantly from guidelines proposed in 1975. These recommendations, based on complications experienced during noncutaneous surgery, are exceedingly conservative and do not take into consideration the different electrosurgical modalities and varying degrees of EMI risk. In addition, modern cardiac devices have evolved significantly with increased sophistication in protection from EMI. A survey of dermatologic surgeons demonstrated low compliance with these existing guidelines. METHODS, RESULTS, AND
CONCLUSIONS: Based on a review of the literature and current electrosurgical and cardiac devices, we discuss the potential impact of conventional dermatologic electrosurgery and new technologies. We propose that new perioperative guidelines are needed to provide appropriate safety, facile implementation, and cost-effective care for patients with modern implantable cardiac devices.

Entities:  

Mesh:

Year:  2005        PMID: 16042939

Source DB:  PubMed          Journal:  Dermatol Surg        ISSN: 1076-0512            Impact factor:   3.398


  3 in total

Review 1.  Deep brain stimulation and electromagnetic interference.

Authors:  Shervin Rahimpour; Musa Kiyani; Sarah E Hodges; Dennis A Turner
Journal:  Clin Neurol Neurosurg       Date:  2021-02-25       Impact factor: 1.876

2.  Do we need to establish guidelines for patients with neuromodulation implantable devices, including spinal cord stimulators undergoing nonspinal surgeries?

Authors:  Ramsis F Ghaly; Tatiana Tverdohleb; Kenneth D Candido; Nebojsa Nick Knezevic
Journal:  Surg Neurol Int       Date:  2016-02-15

3.  27.12 MHz Radiofrequency Ablation for Benign Cutaneous Lesions.

Authors:  Dong Hyun Kim; Dong Ju Hyun; Raymonde Piquette; Clément Beaumont; Lucie Germain; Danielle Larouche
Journal:  Biomed Res Int       Date:  2016-04-05       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.