Diffusion in complex heterogeneous structures, for example, the neural fiber system, is non-gaussian. Recently, several methods have been introduced to address the issue of non-gaussian diffusion in multifiber systems. Some are based on apparent diffusion coefficient (ADC) analysis; and some are based on q-space analysis. Here, using a simple mathematic derivation, ADC-based models are shown to be mathematically self-inconsistent in the presence of non-gaussian diffusion. Monte Carlo simulation on restricted diffusion is applied to demonstrate the poor data fitting that can result from ADC-based models. Specific comparisons are performed between two generalized diffusion tensor imaging methods: one of them is based on ADC analysis, and the other is shown to be consistent with q-space formalism. The issue of imaging asymmetric microstructures is also investigated. Signal phase and spin exchange are necessary to resolve multiple orientations of an asymmetric structure. 2005 Wiley-Liss, Inc

Mesh:

Year:  2005        PMID: 16032684     DOI: 10.1002/mrm.20579

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

Review 1.  A review of diffusion tensor magnetic resonance imaging computational methods and software tools.

Authors:  Khader M Hasan; Indika S Walimuni; Humaira Abid; Klaus R Hahn
Journal:  Comput Biol Med       Date:  2010-11-18       Impact factor: 4.589

Review 2.  Diffusion tensor imaging and beyond.

Authors:  Jacques-Donald Tournier; Susumu Mori; Alexander Leemans
Journal:  Magn Reson Med       Date:  2011-04-05       Impact factor: 4.668

3.  In vivo generalized diffusion tensor imaging (GDTI) using higher-order tensors (HOT).

Authors:  Chunlei Liu; Sarah C Mang; Michael E Moseley
Journal:  Magn Reson Med       Date:  2010-01       Impact factor: 4.668

4.  Comparison of Diffusion MRI Acquisition Protocols for the In Vivo Characterization of the Mouse Spinal Cord: Variability Analysis and Application to an Amyotrophic Lateral Sclerosis Model.

Authors:  Matteo Figini; Alessandro Scotti; Stefania Marcuzzo; Silvia Bonanno; Francesco Padelli; Victoria Moreno-Manzano; José Manuel García-Verdugo; Pia Bernasconi; Renato Mantegazza; Maria Grazia Bruzzone; Ileana Zucca
Journal:  PLoS One       Date:  2016-08-25       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.