Literature DB >> 16032660

Water in tendon: orientational analysis of the free induction decay.

Lada V Krasnosselskaia1, Gary D Fullerton, Stephen J Dodd, Ivan L Cameron.   

Abstract

The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a specimen and the external magnetic field is changed from the "magic angle" of 54.7 degrees to 0 degrees. The strength of residual dipolar interactions between water protons was estimated by orientational analysis of the signal intensity to be equal to 780 Hz. Apparent signal maxima are observed at orientations 8-13 degrees away from 54.7 degrees due to an inhomogeneous contribution to the decay. A small fraction of total water in tendon is detectable at all orientations and exhibits a shift in the precession frequency. It is hypothesized that this water fraction resides in the interconnecting gaps at the ends of collagen molecules. The gaps have a disordered environment that allows for a zero time average of dipolar interactions. Measured frequency and phase shifts are interpreted as signatures of the bulk magnetic susceptibility effect due to geometry of the cavity formed by adjacent gaps at the ends of the collagen molecules. The multiexponentiality of the FID decay is hypothesized to be due to the exchange between orientationally restricted water structured along the length of the collagen molecule and disordered water in the cavity. 2005 Wiley-Liss, Inc

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16032660     DOI: 10.1002/mrm.20540

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Review. The Agfa Mayneord lecture: MRI of short and ultrashort T₂ and T₂* components of tissues, fluids and materials using clinical systems.

Authors:  G M Bydder
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  Quantitative bi-component T2* analysis of histologically normal Achilles tendons.

Authors:  Eric Y Chang; Jiang Du; Sheronda Statum; Chantal Pauli; Christine B Chung
Journal:  Muscles Ligaments Tendons J       Date:  2015-07-03

Review 3.  Magnetic resonance imaging of short T2 relaxation components in the musculoskeletal system.

Authors:  Graeme M Bydder; Christine B Chung
Journal:  Skeletal Radiol       Date:  2009-03       Impact factor: 2.199

Review 4.  MR imaging of articular cartilage physiology.

Authors:  Jung-Ah Choi; Garry E Gold
Journal:  Magn Reson Imaging Clin N Am       Date:  2011-05       Impact factor: 2.266

5.  T2 * MR relaxometry and ligament volume are associated with the structural properties of the healing ACL.

Authors:  Alison M Biercevicz; Martha M Murray; Edward G Walsh; Danny L Miranda; Jason T Machan; Braden C Fleming
Journal:  J Orthop Res       Date:  2013-12-16       Impact factor: 3.494

6.  Ultrashort echo time magnetization transfer (UTE-MT) imaging and modeling: magic angle independent biomarkers of tissue properties.

Authors:  Ya-Jun Ma; Hongda Shao; Jiang Du; Eric Y Chang
Journal:  NMR Biomed       Date:  2016-09-06       Impact factor: 4.044

7.  Rotator cuff tendon assessment using magic-angle insensitive 3D ultrashort echo time cones magnetization transfer (UTE-Cones-MT) imaging and modeling with histological correlation.

Authors:  Yanchun Zhu; Xin Cheng; Yajun Ma; Jonathan H Wong; Yaoqin Xie; Jiang Du; Eric Y Chang
Journal:  J Magn Reson Imaging       Date:  2017-12-08       Impact factor: 4.813

8.  T2* relaxometry and volume predict semi-quantitative histological scoring of an ACL bridge-enhanced primary repair in a porcine model.

Authors:  Alison M Biercevicz; Benedikt L Proffen; Martha M Murray; Edward G Walsh; Braden C Fleming
Journal:  J Orthop Res       Date:  2015-04-10       Impact factor: 3.494

Review 9.  Magnetic susceptibility anisotropy outside the central nervous system.

Authors:  Russell Dibb; Luke Xie; Hongjiang Wei; Chunlei Liu
Journal:  NMR Biomed       Date:  2016-05-16       Impact factor: 4.044

10.  Anisotropic analysis of multi-component T2 and T1ρ relaxations in achilles tendon by NMR spectroscopy and microscopic MRI.

Authors:  Nian Wang; Yang Xia
Journal:  J Magn Reson Imaging       Date:  2013-01-24       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.