Literature DB >> 16028892

Fluorescence imaging with one nanometer accuracy: application to molecular motors.

Ahmet Yildiz1, Paul R Selvin.   

Abstract

We introduce the technique of FIONA, fluorescence imaging with one nanometer accuracy. This is a fluorescence technique that is able to localize the position of a single dye within approximately 1 nm in the x-y plane. It is done simply by taking the point spread function of a single fluorophore excited with wide field illumination and locating the center of the fluorescent spot by a two-dimensional Gaussian fit. We motivate the development of FIONA by unraveling the walking mechanism of the molecular motors myosin V, myosin VI, and kinesin. We find that they all walk in a hand-over-hand fashion.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16028892     DOI: 10.1021/ar040136s

Source DB:  PubMed          Journal:  Acc Chem Res        ISSN: 0001-4842            Impact factor:   22.384


  94 in total

1.  Quantifying subpixel accuracy: an experimental method for measuring accuracy in image-correlation-based, single-particle tracking.

Authors:  Christopher D Saunter
Journal:  Biophys J       Date:  2010-04-21       Impact factor: 4.033

2.  Improved hidden Markov models for molecular motors, part 2: extensions and application to experimental data.

Authors:  Sheyum Syed; Fiona E Müllner; Paul R Selvin; Fred J Sigworth
Journal:  Biophys J       Date:  2010-12-01       Impact factor: 4.033

3.  Improved hidden Markov models for molecular motors, part 1: basic theory.

Authors:  Fiona E Müllner; Sheyum Syed; Paul R Selvin; Fred J Sigworth
Journal:  Biophys J       Date:  2010-12-01       Impact factor: 4.033

4.  Myosin VI must dimerize and deploy its unusual lever arm in order to perform its cellular roles.

Authors:  Monalisa Mukherjea; M Yusuf Ali; Carlos Kikuti; Daniel Safer; Zhaohui Yang; Helena Sirkia; Virginie Ropars; Anne Houdusse; David M Warshaw; H Lee Sweeney
Journal:  Cell Rep       Date:  2014-08-21       Impact factor: 9.423

5.  Fingerprinting single molecules in vivo.

Authors:  Julio M Fernandez
Journal:  Biophys J       Date:  2005-12       Impact factor: 4.033

Review 6.  High-resolution, single-molecule measurements of biomolecular motion.

Authors:  William J Greenleaf; Michael T Woodside; Steven M Block
Journal:  Annu Rev Biophys Biomol Struct       Date:  2007

7.  Agnostic particle tracking for three-dimensional motion of cellular granules and membrane-tethered bead dynamics.

Authors:  Kalpit V Desai; T Gary Bishop; Leandra Vicci; E Timothy O'Brien; Russell M Taylor; Richard Superfine
Journal:  Biophys J       Date:  2007-11-30       Impact factor: 4.033

8.  Fast fluorescence laser tracking microrheometry. I: instrument development.

Authors:  Maxine Jonas; Hayden Huang; Roger D Kamm; Peter T C So
Journal:  Biophys J       Date:  2007-10-26       Impact factor: 4.033

9.  Unique dynamics and exocytosis properties of GABAergic synaptic vesicles revealed by three-dimensional single vesicle tracking.

Authors:  Chungwon Park; Xingxiang Chen; Chong-Li Tian; Gyu Nam Park; Nicolas Chenouard; Hunki Lee; Xin Yi Yeo; Sangyong Jung; Richard W Tsien; Guo-Qiang Bi; Hyokeun Park
Journal:  Proc Natl Acad Sci U S A       Date:  2021-03-02       Impact factor: 11.205

Review 10.  Single-molecule nanometry for biological physics.

Authors:  Hajin Kim; Taekjip Ha
Journal:  Rep Prog Phys       Date:  2012-12-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.