Literature DB >> 16028241

Multislice continuous arterial spin-labeled perfusion MRI in patients with chronic occlusive cerebrovascular disease: a correlative study with CO2 PET validation.

Hirohiko Kimura1, Hirotsugu Kado, Yoshio Koshimoto, Tatsurou Tsuchida, Yoshiharu Yonekura, Harumi Itoh.   

Abstract

PURPOSE: To compare the use of multislice continuous arterial spin labeling (CASL) and CO(2) positron emission tomography (PET) to assess CBF in patients with chronic occlusive cerebrovascular disease for the validation of quantitative CASL perfusion in an altered hemodynamic state.
MATERIALS AND METHODS: Eleven patients with occlusive carotid artery disease were studied with CASL and conventional MRI. Cerebral blood flow (CBF) was also measured with O(15)-labeled CO(2) gas using a whole-body PET scanner. The average values within region of interests (ROIs) drawn on coregistered CASL and PET images were used for the linear regression analysis and to assess the effect of transit time on the quantification using CASL. RESULT: In all patients there was a significant correlation between the CBF values from CASL and PET (r = 0.71 +/- 0.07, P < 0.001). The slope of regression lines varied widely among patients (0.54-1.77). Longer transit times were estimated in four of 11 patients in the hypoperfusion region.
CONCLUSION: Quantification of CBF using CASL is feasible and reasonable, even when employed in a routine clinical setting. However, the long transit time may lead to underestimation of the affected side in occlusive cerebrovascular disease. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16028241     DOI: 10.1002/jmri.20382

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  22 in total

1.  MR perfusion imaging by alternate slab width inversion recovery arterial spin labeling (AIRASL): a technique with higher signal-to-noise ratio at 3.0 T.

Authors:  Yasuhiro Fujiwara; Hirohiko Kimura; Tosiaki Miyati; Hiroyuki Kabasawa; Tsuyoshi Matsuda; Yoshiyuki Ishimori; Isao Yamaguchi; Toshiki Adachi
Journal:  MAGMA       Date:  2012-01-13       Impact factor: 2.310

2.  Arterial spin-labeling magnetic resonance imaging: the timing of regional maximal perfusion-related signal intensity revealed by a multiphase technique.

Authors:  Tomoyuki Noguchi; Takashi Yoshiura; Akio Hiwatashi; Osamu Togao; Koji Yamashita; Eiki Nagao; Hiroshi Honda
Journal:  Jpn J Radiol       Date:  2011-12-16       Impact factor: 2.374

3.  Hemodynamic studies of intracranial dural arteriovenous fistulas using arterial spin-labeling MR imaging.

Authors:  T Noguchi; H Irie; Y Takase; M Kawashima; T Ootsuka; M Nishihara; Y Egashira; J Nojiri; T Matsushima; S Kudo
Journal:  Interv Neuroradiol       Date:  2010-12-17       Impact factor: 1.610

4.  Measurement of cerebral perfusion with arterial spin labeling: Part 2. Applications.

Authors:  Gregory G Brown; Camellia Clark; Thomas T Liu
Journal:  J Int Neuropsychol Soc       Date:  2007-05       Impact factor: 2.892

Review 5.  Clinical neuroimaging using arterial spin-labeled perfusion magnetic resonance imaging.

Authors:  Ronald L Wolf; John A Detre
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

6.  Comparison of arterial transit times estimated using arterial spin labeling.

Authors:  Yufen Chen; Danny J J Wang; John A Detre
Journal:  MAGMA       Date:  2011-08-24       Impact factor: 2.310

7.  Pseudocontinuous arterial spin labeling quantifies relative cerebral blood flow in acute stroke.

Authors:  Daymara A Hernandez; Reinoud P H Bokkers; Raymond V Mirasol; Marie Luby; Erica C Henning; José G Merino; Steven Warach; Lawrence L Latour
Journal:  Stroke       Date:  2012-02-16       Impact factor: 7.914

8.  Bayesian Estimation of CBF Measured by DSC-MRI in Patients with Moyamoya Disease: Comparison with 15O-Gas PET and Singular Value Decomposition.

Authors:  S Hara; Y Tanaka; S Hayashi; M Inaji; T Maehara; M Hori; S Aoki; K Ishii; T Nariai
Journal:  AJNR Am J Neuroradiol       Date:  2019-10-10       Impact factor: 3.825

9.  Evaluation of retained products of conception using pulsed continuous arterial spin-labeling MRI: clinical feasibility and initial results.

Authors:  Nobuyuki Kosaka; Yasuhiro Fujiwara; Tetsuji Kurokawa; Tsuyoshi Matsuda; Masayuki Kanamoto; Naoyuki Takei; Kenji Takata; Jin Takahashi; Yoshio Yoshida; Hirohiko Kimura
Journal:  MAGMA       Date:  2018-03-16       Impact factor: 2.310

10.  Arterial spin-labeling MR imaging of cerebral hemorrhages.

Authors:  Tomoyuki Noguchi; Masashi Nishihara; Yoshiaki Egashira; Shinya Azama; Tetsuyoshi Hirai; Isao Kitano; Yusuke Yakushiji; Masatou Kawashima; Hiroyuki Irie
Journal:  Neuroradiology       Date:  2015-08-18       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.