Arterial spin-labeling magnetic resonance imaging: the timing of regional maximal perfusion-related signal intensity revealed by a multiphase technique.

Tomoyuki Noguchi1, Takashi Yoshiura, Akio Hiwatashi, Osamu Togao, Koji Yamashita, Eiki Nagao, Hiroshi Honda.   

Abstract

PURPOSE: We investigated the time interval from labeling to peak (TLP) of perfusion-signal intensity (SIs) in normal brain using a multiphase arterial spin-labeling (ASL) magnetic resonance imaging (MRI) technique as a fundamental study to assess the temporal characteristics of perfusion SIs.
MATERIALS AND METHODS: Twenty temporal phases of a pulsed ASL-MRI [QUASAR, quantitative signal targeting by alternating radiofrequency pulses (STAR) labeling of arterial regions] in single-slice imaging were performed in 9 volunteers. Perfusion SIs were measured and TLPs were calculated in 14 regions of interest (ROIs), 7 in each hemisphere: thalamus, lentiform nucleus, medial frontal cortex in the anterior cerebral artery (ACA) territory, temporal cortex in the middle cerebral artery (MCA) territory, medial occipital cortex in the posterior cerebral artery (PCA) territory, anterior watershed region (AWR) and posterior watershed region (PWR).
RESULTS: Mean TLP varied with ROI (region and mean ± standard deviation in seconds): thalamus, 1.60 ± 0.11; lentiform nucleus, 1.52 ± 0.11; ACA territory, 1.53 ± 0.16; MCA territory, 1.59 ± 0.18; PCA territory, 1.68 ± 0.20; AWR, 1.79 ± 0.14; PWR, 2.00 ± 0.20. TLP in the PWR was significantly longer than those in all other regions except the AWR, and TLP in the AWR was significantly longer than those in the lentiform nucleus and the ACA territory.
CONCLUSION: Our results revealed regional differences in the temporal characteristics of perfusion SIs on ASL-MRI.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22173560     DOI: 10.1007/s11604-011-0025-8

Source DB:  PubMed          Journal:  Jpn J Radiol        ISSN: 1867-1071            Impact factor:   2.374


  32 in total

1.  Susceptibility contrast and arterial spin labeled perfusion MRI in cerebrovascular disease.

Authors:  Ronald L Wolf; David C Alsop; Michael L McGarvey; Joseph A Maldjian; Jiongjiong Wang; John A Detre
Journal:  J Neuroimaging       Date:  2003-01       Impact factor: 2.486

2.  Pediatric perfusion imaging using pulsed arterial spin labeling.

Authors:  Jiongjiong Wang; Daniel J Licht; Geon-Ho Jahng; Chia-Shang Liu; Joan T Rubin; John Haselgrove; Robert A Zimmerman; John A Detre
Journal:  J Magn Reson Imaging       Date:  2003-10       Impact factor: 4.813

3.  Model-free arterial spin labeling quantification approach for perfusion MRI.

Authors:  Esben Thade Petersen; Tchoyoson Lim; Xavier Golay
Journal:  Magn Reson Med       Date:  2006-02       Impact factor: 4.668

4.  Quantitative perfusion imaging with pulsed arterial spin labeling: a phantom study.

Authors:  Tomoyuki Noguchi; Takashi Yoshiura; Akio Hiwatashi; Osamu Togao; Koji Yamashita; Kouji Kobayashi; Futoshi Mihara; Hiroshi Honda
Journal:  Magn Reson Med Sci       Date:  2007       Impact factor: 2.471

5.  A comparison of one-shot and recovery methods in T1 imaging.

Authors:  A P Crawley; R M Henkelman
Journal:  Magn Reson Med       Date:  1988-05       Impact factor: 4.668

6.  MR perfusion studies with T1-weighted echo planar imaging.

Authors:  K K Kwong; D A Chesler; R M Weisskoff; K M Donahue; T L Davis; L Ostergaard; T A Campbell; B R Rosen
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

7.  Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency.

Authors:  R R Edelman; B Siewert; D G Darby; V Thangaraj; A C Nobre; M M Mesulam; S Warach
Journal:  Radiology       Date:  1994-08       Impact factor: 11.105

8.  Comparison of EPISTAR and T2*-weighted gadolinium-enhanced perfusion imaging in patients with acute cerebral ischemia.

Authors:  B Siewert; G Schlaug; R R Edelman; S Warach
Journal:  Neurology       Date:  1997-03       Impact factor: 9.910

9.  Comparison of FAIR technique with different inversion times and post contrast dynamic perfusion MRI in chronic occlusive cerebrovascular disease.

Authors:  Kazuhide Yoneda; Masafumi Harada; Naomi Morita; Hiromu Nishitani; Masaaki Uno; Tsuyoshi Matsuda
Journal:  Magn Reson Imaging       Date:  2003-09       Impact factor: 2.546

10.  Noninvasive perfusion imaging of human brain tumors with EPISTAR.

Authors:  J Gaa; S Warach; P Wen; V Thangaraj; P Wielopolski; R R Edelman
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

View more
  3 in total

Review 1.  Recent progress in ASL.

Authors:  Luis Hernandez-Garcia; Anish Lahiri; Jonas Schollenberger
Journal:  Neuroimage       Date:  2018-01-03       Impact factor: 6.556

2.  Optimizing MRF-ASL scan design for precise quantification of brain hemodynamics using neural network regression.

Authors:  Anish Lahiri; Jeffrey A Fessler; Luis Hernandez-Garcia
Journal:  Magn Reson Med       Date:  2019-11-21       Impact factor: 3.737

3.  Arterial spin labeling signal ratio between the lesion and contralateral sides for evaluation of acute middle cerebral artery infarct.

Authors:  Junyoung Lee; Dong Woo Park; Young Seo Kim; Hyun Young Kim; Young-Jun Lee
Journal:  Medicine (Baltimore)       Date:  2022-01-14       Impact factor: 1.817

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.