Literature DB >> 1602763

Strip extensiometry for comparison of the mechanical response of bovine, rabbit, and human corneas.

D A Hoeltzel1, P Altman, K Buzard, K Choe.   

Abstract

Specimens of bovine, rabbit, and human corneas were systematically tested in uniaxial tension to experimentally determine their effective nonlinear stress-strain relations, and hysteresis. Cyclic tensile tests were performed over the physiologic load range of the cornea, up to a maximum of 10 percent strain beyond slack strain. Dimensional changes to corneal test specimens, due to varying laboratory environmental conditions, were also assessed. The measured stress-strain data was found to closely fit exponential power function relations typical of collagenous tissues when appropriate account was taken of specimen slack strain. These constitutive relations are very similar for rabbit, human and bovine corneas; there was no significant difference between the species after preconditioning by one cycle. The uniaxial stress strain curves for all species behave similarly in that their tangent moduli increase at high loads and decrease at low loads as a function of cycling. In the bovine and rabbit data, there is a general trend towards more elastic behavior from the first to second cycles, but there is little variation in these parameters from the second to third cycles. In comparison, the human data demonstrates relatively little change between cycles. Increases in width of corneal test specimens, up to a maximum of 2 percent were found to occur under 95 percent relative humidity test conditions over 10 minutes elapsed time test periods, while specimens which were exposed to normal laboratory conditions (45 percent RH) were found to shrink in width up to a maximum of 9.5 percent over the same elapsed time period. The thickness of the test specimens were observed to decrease by 3 percent in 95 percent relative humidity and by 12 percent in 45 percent relative humidity over the same elapsed time period.

Entities:  

Mesh:

Year:  1992        PMID: 1602763     DOI: 10.1115/1.2891373

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  53 in total

1.  Influence of some operational variables on the radial keratotomy operation.

Authors:  J Q Wang; Y J Zeng; X Y Li
Journal:  Br J Ophthalmol       Date:  2000-06       Impact factor: 4.638

2.  Brillouin optical microscopy for corneal biomechanics.

Authors:  Giuliano Scarcelli; Roberto Pineda; Seok Hyun Yun
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-01-20       Impact factor: 4.799

3.  Using Digital Image Correlation to Characterize Local Strains on Vascular Tissue Specimens.

Authors:  Boran Zhou; Suraj Ravindran; Jahid Ferdous; Addis Kidane; Michael A Sutton; Tarek Shazly
Journal:  J Vis Exp       Date:  2016-01-24       Impact factor: 1.355

4.  Characterizing the viscoelastic properties of thin hydrogel-based constructs for tissue engineering applications.

Authors:  Mark Ahearne; Ying Yang; Alicia J El Haj; Kong Y Then; Kuo-Kang Liu
Journal:  J R Soc Interface       Date:  2005-12-22       Impact factor: 4.118

5.  Comparative study of corneal strip extensometry and inflation tests.

Authors:  Ahmed Elsheikh; Kevin Anderson
Journal:  J R Soc Interface       Date:  2005-06-22       Impact factor: 4.118

6.  Poroelastic bulk properties of the tectorial membrane measured with osmotic stress.

Authors:  Kinuko Masaki; Thomas F Weiss; Dennis M Freeman
Journal:  Biophys J       Date:  2006-06-30       Impact factor: 4.033

7.  Patterned corneal collagen crosslinking for astigmatism: computational modeling study.

Authors:  Ibrahim Seven; Abhijit Sinha Roy; William J Dupps
Journal:  J Cataract Refract Surg       Date:  2014-04-24       Impact factor: 3.351

8.  Assessing the effects of riboflavin/UV-A crosslinking on porcine corneal mechanical anisotropy with optical coherence elastography.

Authors:  Manmohan Singh; Jiasong Li; Zhaolong Han; Raksha Raghunathan; Achuth Nair; Chen Wu; Chih-Hao Liu; Salavat Aglyamov; Michael D Twa; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2016-12-19       Impact factor: 3.732

9.  Optical coherence elastography for evaluating customized riboflavin/UV-A corneal collagen crosslinking.

Authors:  Manmohan Singh; Jiasong Li; Srilatha Vantipalli; Zhaolong Han; Kirill V Larin; Michael D Twa
Journal:  J Biomed Opt       Date:  2017-09-01       Impact factor: 3.170

10.  Integrated optical coherence tomography and multielement ultrasound transducer probe for shear wave elasticity imaging of moving tissues.

Authors:  Andrei B Karpiouk; Donald J VanderLaan; Kirill V Larin; Stanislav Y Emelianov
Journal:  J Biomed Opt       Date:  2018-10       Impact factor: 3.170

View more