A study of a normoxic polymer gel dosimeter comprising methacrylic acid, gelatin and tetrakis (hydroxymethyl) phosphonium chloride (MAGAT).

C Hurley1, A Venning, C Baldock.   

Abstract

In this study, the response to ionsing radiation of the normoxic polymer gel dosimeter comprising tetrakis (hydroxymethyl) phosphonium chloride (THPC) with methacrylic acid (MAA) and gelatin, named MAGAT, has been investigated. Using magnetic resonance imaging (MRI), the R2-dose response or change in R2 (DeltaR2) is evaluated for different concentrations of the component chemicals: THPC, MAA, gelatin and hydroquinone (HQ). The formulation for which the MAGAT polymer gel dosimeter had a maximum response was determined, and the spatial and temporal stability for this formulation analyzed. It was found that the formulation that provided the greatest change in R2 was 10 mM THPC, 0-0.05 mM HQ, 6-7% gelatin and 4-6% MAA (evaluated one day post-irradiation). MAGAT polymer gel dosimeters comprising 10mM THPC, 0.05 mM HQ, 6-9% MAA and 4-6% gelatin have shown potential for use in radiation therapy dosimetry.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16026995     DOI: 10.1016/j.apradiso.2005.03.014

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  9 in total

1.  Optical scanner for 3D radiotherapy polymer gel dosimetry.

Authors:  Piotr Sobotka; Marek Kozicki; Piotr Maras; Ł Boniecki; K Kacperski; A W Domański
Journal:  Acta Phys Pol A       Date:  2012-11       Impact factor: 0.577

Review 2.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

3.  Optimization of the imaging protocol of an X-ray CT scanner for evaluation of normoxic polymer gel dosimeters.

Authors:  Brindha Subramanian; Paul B Ravindran; Clive Baldock
Journal:  J Med Phys       Date:  2006-04

4.  Determine the Dose Distribution Using Ultrasound Parameters in MAGIC-f Polymer Gels.

Authors:  Hossein Masoumi; Manijhe Mokhtari-Dizaji; Azim Arbabi; Mohsen Bakhshandeh
Journal:  Dose Response       Date:  2016-02-11       Impact factor: 2.658

5.  MAGAT gel and EBT2 film-based dosimetry for evaluating source plugging-based treatment plan in Gamma Knife stereotactic radiosurgery.

Authors:  Gopishankar Natanasabapathi; Vivekanandhan Subbiah; Shashank Sharad Kale; Goura Kishor Rath; S Senthilkumaran; Sanjay Thulkar; Vellaiyan Subramani; M A Laviraj; Raj Kishor Bisht; A K Mahapatra
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

6.  Dosimetry and Radioenhancement Comparison of Gold Nanoparticles in Kilovoltage and Megavoltage Radiotherapy using MAGAT Polymer Gel Dosimeter.

Authors:  S Farahani; N Riyahi Alam; S Haghgoo; M Khoobi; Gh Geraily; E Gorji
Journal:  J Biomed Phys Eng       Date:  2019-04-01

Review 7.  A Review of PRESAGE Radiochromic Polymer and the Compositions for Application in Radiotherapy Dosimetry.

Authors:  Muhammad Zamir Mohyedin; Hafiz Mohd Zin; Mohd Zulfadli Adenan; Ahmad Taufek Abdul Rahman
Journal:  Polymers (Basel)       Date:  2022-07-16       Impact factor: 4.967

Review 8.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

9.  Indigenously developed multipurpose acrylic head phantom for verification of IMRT using film and gel dosimetry.

Authors:  N Gopishankar; S Vivekanandhan; G K Rath; M A Laviraj; S Senthilkumaran; S S Kale; S Thulkar; R K Bisht; V Subramani
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.