Literature DB >> 16023960

Reagentless amperometric immunosensor for human chorionic gonadotrophin based on direct electrochemistry of horseradish peroxidase.

Jin Chen1, Feng Yan, Zong Dai, Huangxian Ju.   

Abstract

A novel amperometric immunosensor for determination of human serum chorionic gonadotrophin (HCG) was constructed by immobilization of HCG with titania sol-gel on a glassy carbon electrode and the direct electrochemistry of horseradish peroxidase (HRP) labeled to HCG antibody (HRP-anti-HCG). The morphologies of the HCG membrane were characterized to be chemically clean, porous and homogeneous. HRP-anti-HCG was functionally conjugated with the immobilized HCG after incubation in phosphate buffer (PBS) containing HRP-anti-HCG. A direct electron transfer of HRP with a rate constant of 1.35+/-0.40 s(-1) was observed at the HRP-anti-HCG-HCG/titania sol-gel membrane modified electrode in 0.1 M PBS pH 7.0. With a competitive mechanism the differential pulse voltammetric peak current of the immobilized HRP decreased linearly with an increasing HCG concentration from 2.5 to 12.5 mIU/ml in the incubation solution. The HCG immunosensor showed a detection limit of 1.4 mIU/ml, a good accuracy and acceptable precision and reproducibility with an intra-assay CV of 4.7% at 5.0 mIU/ml and an inter-assay precision of 8.1% obtained at 10 mIU/ml. The biosensor displayed a good stability in a storage period of 30 days.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 16023960     DOI: 10.1016/j.bios.2004.10.023

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Long latency of evoked quantal transmitter release from somata of locus coeruleus neurons in rat pontine slices.

Authors:  H-P Huang; S-R Wang; W Yao; C Zhang; Y Zhou; X-W Chen; B Zhang; W Xiong; L-Y Wang; L-H Zheng; M Landry; T Hökfelt; Z-Q D Xu; Z Zhou
Journal:  Proc Natl Acad Sci U S A       Date:  2007-01-16       Impact factor: 11.205

2.  Fouling-resistant biofilter of an anaerobic electrochemical membrane reactor.

Authors:  Qilin Yu; Yaobin Zhang
Journal:  Nat Commun       Date:  2019-10-24       Impact factor: 14.919

3.  A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip.

Authors:  S R Balakrishnan; U Hashim; Subash C B Gopinath; P Poopalan; H R Ramayya; M Iqbal Omar; R Haarindraprasad; P Veeradasan
Journal:  PLoS One       Date:  2015-09-14       Impact factor: 3.240

Review 4.  Antibody-Electroactive Probe Conjugates Based Electrochemical Immunosensors.

Authors:  Mateusz Kondzior; Iwona Grabowska
Journal:  Sensors (Basel)       Date:  2020-04-03       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.