Literature DB >> 16021539

[Lung nodule detection with ultra-low-dose CT in routine follow-up of cancer patients].

I Gergely1, C Neumann, F Reiger, R Dorffner.   

Abstract

PURPOSE: To evaluate the value of an ultra-low-dose CT protocol (ULD-CT) in the dectection of lungnodules in follow-up of cancer patients.
MATERIAL AND METHODS: Between April and August 2003, 72 consecutive patients with a history of malignancy were prospectively examined on a single-slice helical CT scanner (Aquilion, Toshiba) with ULD-CT (120 kV, 5 mAs, D-eff 0.12 mSv) and regular-dose CT (R-CT) (120 kV, 150 mAs, D-eff 4.8 mSv). The ULD-CT examinations were independently evaluated by two radiologists. Afterwards, consensus reading of the ULD-CT and R-CT examinations was done. Individual nodules were classified benign (benign calcifications) and non-benign. The studies were classified in 4 subgroups: 1) non-benign nodule evident; 2) non-benign nodule probable; 3) non-benign nodule possible, but not likely; 4) no-non benign nodule.
RESULTS: ULD-CT detected 180 nodules in 47 patients, while R-CT showed 168 nodules in 39 patients. The sensitivity of ULD-CT was 87 % in detecting nodules regardless of size and 94 % in detecting nodules > or = 5 mm. Regarding the prediction of a case with non-benign nodules (subgroups 1 to 3), the sensitivity of ULD-CT was 94 % and the specificity 75 %.
CONCLUSION: ULD-CT is a good diagnostic tool in detecting lung nodules > or = 5 mm. Radiation dose can be markedly reduced. A negative ULD-CT study excludes non-benign nodules in R-CT with a high probability. In case of a positive ULD-CT, R-CT can be immediately followed.

Entities:  

Mesh:

Year:  2005        PMID: 16021539     DOI: 10.1055/s-2005-858370

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  4 in total

1.  Detection of small pulmonary nodules in high-field MR at 3 T: evaluation of different pulse sequences using porcine lung explants.

Authors:  M Regier; S Kandel; M G Kaul; B Hoffmann; H Ittrich; P M Bansmann; J Kemper; C Nolte-Ernsting; M Heller; G Adam; J Biederer
Journal:  Eur Radiol       Date:  2006-09-30       Impact factor: 5.315

2.  CT dose and image quality in the last three scanner generations.

Authors:  Andreas Christe; Johannes Heverhagen; Christoph Ozdoba; Christian Weisstanner; Stefan Ulzheimer; Lukas Ebner
Journal:  World J Radiol       Date:  2013-11-28

3.  Ultra-low-dose MDCT of the chest: influence on automated lung nodule detection.

Authors:  Ji Young Lee; Myung Jin Chung; Chin A Yi; Kyung Soo Lee
Journal:  Korean J Radiol       Date:  2008 Mar-Apr       Impact factor: 3.500

4.  Acute abdominal pain: value of non-contrast enhanced ultra-low-dose multi-detector row CT as a substitute for abdominal radiographs.

Authors:  Unni K Udayasankar; Jianhai Li; Deborah A Baumgarten; William C Small; Mannudeep K Kalra
Journal:  Emerg Radiol       Date:  2008-07-03
  4 in total