Literature DB >> 1601445

Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex.

D J Edell1, V V Toi, V M McNeil, L D Clark.   

Abstract

Insertable microelectrode arrays can be used to activate neurons or to sense neural signals for use in prosthetics. The relationship of the microelectrodes to the neurons is determined by random alignment and by biocompatibility. Issues that determine the biocompatibility of insertable microelectrode arrays were investigated. Arrays were implanted into the cortex of rabbit brain and fixed to the skull. Following six-month survival, neuron density as a function of distance from the shafts of the arrays was measured to assess destruction of neurons. Results from a limited number of tests indicated that there was minimal tissue response along the sides of the shafts when shafts were well sharpened, had sufficiently small tip angles, and were clean. Tissue was usually more reactive at the tips of the shafts. It was concluded that silicon microshafts of appropriate shaft and tip design were biocompatible along the sides of the shaft, but that relatively severe reactions could be anticipated at the tips. Recording or stimulation sites should be located away from the tips on the sides of the shafts for better coupling with individual neurons. Measurement of neuron density as a function of distance from the shafts was a sensitive and quantitative technique for assessing biocompatibility. Additional measures such as glial density as a function of distance from the shafts, and incidence of microhematoma formation were proposed.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1601445     DOI: 10.1109/10.141202

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  101 in total

1.  Chronically Implanted, Nafion-Coated Ag/AgCl Reference Electrodes for Neurochemical Applications.

Authors:  Parastoo Hashemi; Paul L Walsh; Thomas S Guillot; Julie Gras-Najjar; Pavel Takmakov; Fulton T Crews; R Mark Wightman
Journal:  ACS Chem Neurosci       Date:  2011-11-16       Impact factor: 4.418

2.  Layered nanocomposites from gold nanoparticles for neural prosthetic devices.

Authors:  Huanan Zhang; Jimmy Shih; Jian Zhu; Nicholas A Kotov
Journal:  Nano Lett       Date:  2012-06-26       Impact factor: 11.189

3.  Toward an injectable continuous osmotic glucose sensor.

Authors:  Erik Johannessen; Olga Krushinitskaya; Andrey Sokolov; Häfliger Philipp; Arno Hoogerwerf; Christian Hinderling; Kari Kautio; Jaakko Lenkkeri; Esko Strömmer; Vasily Kondratyev; Tor Inge Tønnessen; Tom Eirik Mollnes; Henrik Jakobsen; Even Zimmer; Bengt Akselsen
Journal:  J Diabetes Sci Technol       Date:  2010-07-01

4.  Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping.

Authors:  T D Y Kozai; T C Marzullo; F Hooi; N B Langhals; A K Majewska; E B Brown; D R Kipke
Journal:  J Neural Eng       Date:  2010-07-19       Impact factor: 5.379

5.  In vivo evaluation of needle force and friction stress during insertion at varying insertion speed into the brain.

Authors:  Fernando Casanova; Paul R Carney; Malisa Sarntinoranont
Journal:  J Neurosci Methods       Date:  2014-08-20       Impact factor: 2.390

6.  Protein adsorption on materials for recording sites on implantable microelectrodes.

Authors:  Jamunanithy Selvakumaran; Joseph L Keddie; David J Ewins; Michael Pycraft Hughes
Journal:  J Mater Sci Mater Med       Date:  2007-06-21       Impact factor: 3.896

7.  A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cord.

Authors:  Kathleen W Meacham; Richard J Giuly; Liang Guo; Shawn Hochman; Stephen P DeWeerth
Journal:  Biomed Microdevices       Date:  2008-04       Impact factor: 2.838

8.  Using a common average reference to improve cortical neuron recordings from microelectrode arrays.

Authors:  Kip A Ludwig; Rachel M Miriani; Nicholas B Langhals; Michael D Joseph; David J Anderson; Daryl R Kipke
Journal:  J Neurophysiol       Date:  2008-12-24       Impact factor: 2.714

9.  Inhibition of the cluster of differentiation 14 innate immunity pathway with IAXO-101 improves chronic microelectrode performance.

Authors:  John K Hermann; Madhumitha Ravikumar; Andrew J Shoffstall; Evon S Ereifej; Kyle M Kovach; Jeremy Chang; Arielle Soffer; Chun Wong; Vishnupriya Srivastava; Patrick Smith; Grace Protasiewicz; Jingle Jiang; Stephen M Selkirk; Robert H Miller; Steven Sidik; Nicholas P Ziats; Dawn M Taylor; Jeffrey R Capadona
Journal:  J Neural Eng       Date:  2018-04       Impact factor: 5.379

10.  Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates.

Authors:  James C Barrese; Naveen Rao; Kaivon Paroo; Corey Triebwasser; Carlos Vargas-Irwin; Lachlan Franquemont; John P Donoghue
Journal:  J Neural Eng       Date:  2013-11-12       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.