Literature DB >> 16013832

Use of automated direct sample introduction with analyte protectants in the GC-MS analysis of pesticide residues.

Tomás Cajka1, Katerina Mastovská, Steven J Lehotay, Jana Hajslová.   

Abstract

Automated large-volume direct sample introduction, or difficult matrix introduction (DMI), was investigated in the determination of 44 pesticide residues possessing a wide range of physico-chemical properties (volatility, polarity, pK(a)) in fruit-based baby food by means of gas chromatography-mass spectrometry (GC-MS) with a quadrupole mass analyzer. DMI has advantages over traditional injection because large volumes (up to 30 microL) of potentially dirty sample extracts can be injected into the GC-MS, but nonvolatile matrix components that would normally contaminate the inlet are removed after every injection. The extra matrix and glass surfaces involved in DMI, however, make the system more prone to the matrix-induced chromatographic enhancement effect, which adversely affects quantification of several pesticides. To overcome this problem, matrix-matched calibration standards and/or the use of analyte protectants were applied in the DMI approach, and the analysis of extracts was also compared before and after undergoing clean-up by dispersive solid-phase extraction. For best quantification, clean-up was still needed, and the combination of matrix-matching with analyte protectants gave the most reproducible results. Depending on the application, however, the addition of analyte protectants (a mixture of 3-ethoxy-1,2-propanediol, L-gulonic acid 3-lactone, and D-sorbitol) to sample extracts and calibration standards in solvent (non-matrix matched), gave satisfactory quantification for most of the 44 pesticides tested. The lowest calibration levels for 34 of the 44 pesticides were < or = 10 ng/g, which meets the standard required by the European Union Baby Food Directive (2003/13/EC).

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16013832     DOI: 10.1002/jssc.200500050

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  4 in total

1.  A High Throughput Method for Measuring Polycyclic Aromatic Hydrocarbons in Seafood Using QuEChERS Extraction and SBSE.

Authors:  Edward A Pfannkoch; John R Stuff; Jacqueline A Whitecavage; John M Blevins; Kathryn A Seely; Jeffery H Moran
Journal:  Int J Anal Chem       Date:  2015-03-19       Impact factor: 1.885

2.  Methodology for non-target screening of sewage sludge using comprehensive two-dimensional gas chromatography coupled to high-resolution mass spectrometry.

Authors:  Cathrin Veenaas; Peter Haglund
Journal:  Anal Bioanal Chem       Date:  2017-06-23       Impact factor: 4.142

3.  Surface display and bioactivity of Bombyx mori acetylcholinesterase on Pichia pastoris.

Authors:  Jie-Xian Dong; Xi Xie; Yong-Sheng He; Ross C Beier; Yuan-Ming Sun; Zhen-Lin Xu; Wei-Jian Wu; Yu-Dong Shen; Zhi-Li Xiao; Li-Na Lai; Hong Wang; Jin-Yi Yang
Journal:  PLoS One       Date:  2013-08-05       Impact factor: 3.240

4.  Direct sample introduction GC-MS/MS for quantification of organic chemicals in mammalian tissues and blood extracted with polymers without clean-up.

Authors:  Andreas Baumer; Beate I Escher; Julia Landmann; Nadin Ulrich
Journal:  Anal Bioanal Chem       Date:  2020-08-15       Impact factor: 4.142

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.