Literature DB >> 16013722

A novel method to correct for pitch and yaw patient setup errors in helical tomotherapy.

Sarah A Boswell1, Robert Jeraj, Kenneth J Ruchala, Gustavo H Olivera, Hazim A Jaradat, Joshua A James, Alonso Gutierrez, Dave Pearson, Gary Frank, T Rock Mackie.   

Abstract

An accurate means of determining and correcting for daily patient setup errors is important to the cancer outcome in radiotherapy. While many tools have been developed to detect setup errors, difficulty may arise in accurately adjusting the patient to account for the rotational error components. A novel, automated method to correct for rotational patient setup errors in helical tomotherapy is proposed for a treatment couch that is restricted to motion along translational axes. In tomotherapy, only a narrow superior/inferior section of the target receives a dose at any instant, thus rotations in the sagittal and coronal planes may be approximately corrected for by very slow continuous couch motion in a direction perpendicular to the scanning direction. Results from proof-of-principle tests indicate that the method improves the accuracy of treatment delivery, especially for long and narrow targets. Rotational corrections about an axis perpendicular to the transverse plane continue to be implemented easily in tomotherapy by adjustment of the initial gantry angle.

Entities:  

Mesh:

Year:  2005        PMID: 16013722     DOI: 10.1118/1.1914543

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Novel correction methods as alternatives for the six-dimensional correction in CyberKnife treatment.

Authors:  Osamu Suzuki; Hiroya Shiomi; Satoaki Nakamura; Fumitoshi Nakayama; Yasuo Yoshioka; Takehiro Inoue
Journal:  Radiat Med       Date:  2007-01-25

2.  Roll and pitch set-up errors during volumetric modulated arc delivery: can adapting gantry and collimator angles compensate?

Authors:  Nienke A Hoffmans-Holtzer; Daan Hoffmans; Max Dahele; Ben J Slotman; Wilko F A R Verbakel
Journal:  Strahlenther Onkol       Date:  2014-11-28       Impact factor: 3.621

3.  The effects of rotational setup errors in total body irradiation using helical tomotherapy.

Authors:  Akira Isobe; Keisuke Usui; Naoya Hara; Keisuke Sasai
Journal:  J Appl Clin Med Phys       Date:  2021-05-24       Impact factor: 2.102

4.  Dosimetric consequences of rotational setup errors with direct simulation in a treatment planning system for fractionated stereotactic radiotherapy.

Authors:  Jean L Peng; Chihray Liu; Yu Chen; Robert J Amdur; Kenneth Vanek; Jonathan G Li
Journal:  J Appl Clin Med Phys       Date:  2011-04-04       Impact factor: 2.102

5.  Statistical process control and verifying positional accuracy of a cobra motion couch using step-wedge quality assurance tool.

Authors:  Diana Binny; Craig M Lancaster; Jamie V Trapp; Scott B Crowe
Journal:  J Appl Clin Med Phys       Date:  2017-07-21       Impact factor: 2.102

6.  Is Halcyon feasible for single thoracic or lumbar vertebral segment SBRT?

Authors:  Fang Li; Jeonghoon Park; Ron Lalonde; Si Young Jang; Maria Stefania diMayorca; John C Flickinger; Andrew Keller; Mohammed Saiful Huq
Journal:  J Appl Clin Med Phys       Date:  2021-11-29       Impact factor: 2.102

7.  Surface imaging, laser positioning or volumetric imaging for breast cancer with nodal involvement treated by helical TomoTherapy.

Authors:  Frederik Crop; David Pasquier; Amandine Baczkiewic; Julie Doré; Lena Bequet; Emeline Steux; Anne Gadroy; Jacqueline Bouillon; Clement Florence; Laurence Muszynski; Mathilde Lacour; Eric Lartigau
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.