Abstract

We developed a fast method to obtain T1 relaxation maps in magnetic resonance imaging (MRI) based on two inversion recovery acquisitions and a reference acquisition, while maintaining high sensitivity by utilizing the full dynamic range of the MRI signal. Optimal inversion times for estimating T1 in the human brain were predicted using standard error propagation theory. In vivo measurements on nine healthy volunteers yielded T1 values of 1094+/-18 ms in gray matter and 746+/-40 ms in white matter, in reasonable agreement with literature values using conventional approaches. The proposed method should be useful for clinical studies because the T1 maps can be obtained within a few seconds.

Entities:  

Mesh:

Year:  2005        PMID: 16013709      PMCID: PMC2443728          DOI: 10.1118/1.1915014

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  FAIR exempting separate T (1) measurement (FAIREST): a novel technique for online quantitative perfusion imaging and multi-contrast fMRI.

Authors:  S Lai; J Wang; G H Jahng
Journal:  NMR Biomed       Date:  2001 Nov-Dec       Impact factor: 4.044

2.  High-speed multislice T1 mapping using inversion-recovery echo-planar imaging.

Authors:  R J Ordidge; P Gibbs; B Chapman; M K Stehling; P Mansfield
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

3.  A general approach to error estimation and optimized experiment design, applied to multislice imaging of T1 in human brain at 4.1 T.

Authors:  G F Mason; W J Chu; H P Hetherington
Journal:  J Magn Reson       Date:  1997-05       Impact factor: 2.229

4.  Measurement of changes in tissue temperature using MR imaging.

Authors:  R J Dickinson; A S Hall; A J Hind; I R Young
Journal:  J Comput Assist Tomogr       Date:  1986 May-Jun       Impact factor: 1.826

5.  A comparison of one-shot and recovery methods in T1 imaging.

Authors:  A P Crawley; R M Henkelman
Journal:  Magn Reson Med       Date:  1988-05       Impact factor: 4.668

6.  Accurate T1 determination from inversion recovery images: application to human brain at 4 Tesla.

Authors:  S G Kim; X Hu; K Uğurbil
Journal:  Magn Reson Med       Date:  1994-04       Impact factor: 4.668

7.  MR perfusion studies with T1-weighted echo planar imaging.

Authors:  K K Kwong; D A Chesler; R M Weisskoff; K M Donahue; T L Davis; L Ostergaard; T A Campbell; B R Rosen
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

8.  Strategies and tactics in NMR imaging relaxation time measurements. I. Minimizing relaxation time errors due to image noise--the ideal case.

Authors:  R J Kurland
Journal:  Magn Reson Med       Date:  1985-04       Impact factor: 4.668

9.  Establishing norms for age-related changes in proton T1 of human brain tissue in vivo.

Authors:  S Cho; D Jones; W E Reddick; R J Ogg; R G Steen
Journal:  Magn Reson Imaging       Date:  1997       Impact factor: 2.546

10.  Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo.

Authors:  S D Wolff; R S Balaban
Journal:  Magn Reson Med       Date:  1989-04       Impact factor: 4.668

View more
  5 in total

1.  Comparison of T1 mapping and fixed T1 method for dynamic contrast-enhanced MRI perfusion in brain gliomas.

Authors:  G M Conte; L Altabella; A Castellano; V Cuccarini; A Bizzi; M Grimaldi; A Costa; M Caulo; A Falini; N Anzalone
Journal:  Eur Radiol       Date:  2019-04-10       Impact factor: 5.315

Review 2.  Dynamic Contrast-Enhanced MR Imaging in Head and Neck Cancer: Techniques and Clinical Applications.

Authors:  S Gaddikeri; R S Gaddikeri; T Tailor; Y Anzai
Journal:  AJNR Am J Neuroradiol       Date:  2015-10-01       Impact factor: 3.825

3.  Increased cerebral water content in hemodialysis patients.

Authors:  Kathrin Reetz; Zaheer Abbas; Ana Sofia Costa; Vincent Gras; Frances Tiffin-Richards; Shahram Mirzazade; Bernhard Holschbach; Rolf Dario Frank; Athina Vassiliadou; Thilo Krüger; Frank Eitner; Theresa Gross; Jörg Bernhard Schulz; Jürgen Floege; Nadim Jon Shah
Journal:  PLoS One       Date:  2015-03-31       Impact factor: 3.240

Review 4.  Perfusion magnetic resonance imaging: a comprehensive update on principles and techniques.

Authors:  Geon-Ho Jahng; Ka-Loh Li; Leif Ostergaard; Fernando Calamante
Journal:  Korean J Radiol       Date:  2014-09-12       Impact factor: 3.500

5.  Evaluation of B1 inhomogeneity effect on DCE-MRI data analysis of brain tumor patients at 3T.

Authors:  Anirban Sengupta; Rakesh Kumar Gupta; Anup Singh
Journal:  J Transl Med       Date:  2017-12-02       Impact factor: 5.531

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.