Literature DB >> 11746944

FAIR exempting separate T (1) measurement (FAIREST): a novel technique for online quantitative perfusion imaging and multi-contrast fMRI.

S Lai1, J Wang, G H Jahng.   

Abstract

A new pulse sequence, dubbed FAIR exempting separate T(1) measurement (FAIREST) in which a slice-selective saturation recovery acquisition is added in addition to the standard FAIR (flow-sensitive alternating inversion recovery) scheme, was developed for quantitative perfusion imaging and multi-contrast fMRI. The technique allows for clean separation between and thus simultaneous assessment of BOLD and perfusion effects, whereas quantitative cerebral blood flow (CBF) and tissue T(1) values are monitored online. Online CBF maps were obtained using the FAIREST technique and the measured CBF values were consistent with the off-line CBF maps obtained from using the FAIR technique in combination with a separate sequence for T(1) measurement. Finger tapping activation studies were carried out to demonstrate the applicability of the FAIREST technique in a typical fMRI setting for multi-contrast fMRI. The relative CBF and BOLD changes induced by finger-tapping were 75.1 +/- 18.3 and 1.8 +/- 0.4%, respectively, and the relative oxygen consumption rate change was 2.5 +/- 7.7%. The results from correlation of the T(1) maps with the activation images on a pixel-by-pixel basis show that the mean T(1) value of the CBF activation pixels is close to the T(1) of gray matter while the mean T(1) value of the BOLD activation pixels is close to the T(1) range of blood and cerebrospinal fluid. Copyright 2001 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11746944     DOI: 10.1002/nbm.738

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  5 in total

Review 1.  Magnetic resonance perfusion imaging without contrast media.

Authors:  Petros Martirosian; Andreas Boss; Christina Schraml; Nina F Schwenzer; Hansjörg Graf; Claus D Claussen; Fritz Schick
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-08       Impact factor: 9.236

Review 2.  Foundations of advanced magnetic resonance imaging.

Authors:  Roland Bammer; Stefan Skare; Rexford Newbould; Chunlei Liu; Vincent Thijs; Stefan Ropele; David B Clayton; Gunnar Krueger; Michael E Moseley; Gary H Glover
Journal:  NeuroRx       Date:  2005-04

3.  Sensitive and fast T1 mapping based on two inversion recovery images and a reference image.

Authors:  Geon-Ho Jahng; Lara Stables; Andreas Ebel; Gerald B Matson; Dieter J Meyerhoff; Michael W Weiner; Norbert Schuff
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

4.  Comparison of PASL, PCASL, and background-suppressed 3D PCASL in mild cognitive impairment.

Authors:  Sudipto Dolui; Marta Vidorreta; Ze Wang; Ilya M Nasrallah; Abass Alavi; David A Wolk; John A Detre
Journal:  Hum Brain Mapp       Date:  2017-07-24       Impact factor: 5.038

5.  Improved perfusion-weighted MRI by a novel double inversion with proximal labeling of both tagged and control acquisitions.

Authors:  Geon-Ho Jahng; Xiao-Ping Zhu; Gerald B Matson; Michael W Weiner; Norbert Schuff
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.