Routine chest radiography after permanent pacemaker implantation: is it necessary?

N C Edwards1, M Varma, D W Pitcher.   

Abstract

BACKGROUND AND AIMS: Chest radiographs (CXRs) are performed routinely after permanent pacemaker implantation to identify pacemaker lead position and exclude pneumothorax. We assessed the clinical value and need for this procedure.
DESIGN: Retrospective analysis of pacemaker data and CXRs following permanent pacemaker insertion between December 2002 and February 2004.
MATERIALS AND METHODS: Post-procedural CXRs were available in 125/126 consecutive patients after either first endocardial pacemaker implantation or insertion of at least one new lead. Subclavian vein puncture was used for venous access in all cases. CXRs were examined to establish the incidence of pneumothorax and assess pacing lead positions. The clinical records were examined in all patients who had subsequent CXRs or a further pacemaker procedure to identify the indication for these and to establish whether CXR had influenced patient management.
RESULTS: In total, 192 post-procedural CXRs were performed, either postero-anterior (PA) and/or lateral views. Ventricular and/or atrial pacing lead contour and electrode position was considered radiographically appropriate in 86% CXRs. Fourteen per cent of post-procedural radiographs were considered to have radiologically sub-optimal pacemaker lead positioning. None of the patients with these "abnormal" radiographs experienced subsequent pacemaker complications or had further radiographs recorded at a later date. Later repeat CXRs were performed in 16 patients (13%) but only 3 patients (2%) had pacing abnormalities as the primary indication. All three had satisfactory pacing lead position on initial post-implantation and later radiographs, but required further procedures for lead re-positioning. Iatrogenic pneumothorax occurred in one patient (incidence 0.8%) in our series. CXR confirmed the clinical diagnosis and allowed an assessment of size to guide treatment.
CONCLUSION: Routine CXR after permanent pacemaker insertion is not necessary in uncomplicated cases with adequate pacing characteristics.

Entities:  

Mesh:

Year:  2005        PMID: 16006698

Source DB:  PubMed          Journal:  J Postgrad Med        ISSN: 0022-3859            Impact factor:   1.476


  4 in total

1.  New Method of Cardiac Lead Evaluation Using Chest Radiography.

Authors:  Rafal Mlynarski; Sebastian Glowoc; Agnieszka Mlynarska; Krzysztof Golba
Journal:  Medicina (Kaunas)       Date:  2022-02-01       Impact factor: 2.430

2.  Where does it lead? Imaging features of cardiovascular implantable electronic devices on chest radiograph and CT.

Authors:  Rotem S Lanzman; Joachim Winter; Dirk Blondin; Günter Fürst; Axel Scherer; Falk R Miese; Suhny Abbara; Patric Kröpil
Journal:  Korean J Radiol       Date:  2011-08-24       Impact factor: 3.500

3.  Double left ventricular pacing following accidental malpositioning of the right ventricular electrode during implantation of a cardiac resynchronization therapy device.

Authors:  Ruediger Dissmann; Udo Wolthoff; Markus Zabel
Journal:  J Cardiothorac Surg       Date:  2013-06-27       Impact factor: 1.637

4.  Pacemaker lead malposition in the left atrial roof is masked by normal pacing thresholds.

Authors:  Claus Rath; Martin Andreas; Caesar Khazen; Dominik Wiedemann; Andreas Habertheuer; Alfred Kocher
Journal:  J Cardiothorac Surg       Date:  2014-03-20       Impact factor: 1.637