Literature DB >> 16000442

Comparative recovery of microorganisms from BacT/ALERT plastic and glass FA and FN blood culture bottles.

J A Riley1, B J Heiter, P P Bourbeau.   

Abstract

bioMerieux, Inc., has recently introduced plastic bottles to replace glass bottles for use in the BacT/ALERT blood culture system. We compared the performance of the plastic to the glass bottles in a large clinical evaluation. Two blood cultures were collected from each patient, one using glass FA (aerobic) and FN (anaerobic) bottles and one using plastic FA and FN bottles. Of the 4,040 sets of four bottles collected, 3,110 contained the recommended 8 to 12 ml of blood, yielding 524 microorganisms with 359 judged to be clinically significant. Of the 359 significant organisms, 255 were recovered in either one or two bottles from both pairs of bottles in a set while 56 organisms were recovered only from the glass bottles and 48 were recovered only from the plastic bottles (P, not significant [NS]). Of the 286 significant organisms recovered only in the FA bottles (glass and plastic), 180 were recovered in both bottles, 57 in the plastic bottles only, and 49 in the glass bottles only (P, NS). Of the 303 significant organisms recovered in the FN bottles only (glass and plastic), 212 were recovered in both bottles, 46 in the plastic bottles only, and 45 in the glass bottles only (P, NS). For individual organisms, the only significant difference in recovery was obtained for Escherichia coli, with more isolates recovered in the FN plastic than in the FN glass bottles (P = 0.02). These data suggest that recovery of microorganisms with plastic FA/FN bottles is at least equal to that with glass FA/FN bottles while offering greater safety for users.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16000442      PMCID: PMC1169184          DOI: 10.1128/JCM.43.7.3244-3246.2005

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  4 in total

1.  Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia.

Authors:  M P Weinstein; S Mirrett; L G Reimer; M L Wilson; S Smith-Elekes; C R Chuard; K L Joho; L B Reller
Journal:  J Clin Microbiol       Date:  1995-04       Impact factor: 5.948

2.  Controlled comparison of original vented aerobic fan medium with new nonvented BacT/ALERT FA medium for culturing blood.

Authors:  S Mirrett; R J Everts; L B Reller
Journal:  J Clin Microbiol       Date:  2001-06       Impact factor: 5.948

3.  Controlled clinical comparison of plastic versus glass bottles of BacT/ALERT PF medium for culturing blood from children.

Authors:  Cathy A Petti; Stanley Mirrett; Christopher W Woods; L Barth Reller
Journal:  J Clin Microbiol       Date:  2005-01       Impact factor: 5.948

4.  Controlled evaluation of BacT/alert standard anaerobic and FAN anaerobic blood culture bottles for the detection of bacteremia and fungemia.

Authors:  M L Wilson; M P Weinstein; S Mirrett; L G Reimer; R J Feldman; C R Chuard; L B Reller
Journal:  J Clin Microbiol       Date:  1995-09       Impact factor: 5.948

  4 in total
  2 in total

1.  Assessing how many blood cultures are needed for detecting bloodstream infections.

Authors:  Federico G Nicola
Journal:  J Clin Microbiol       Date:  2008-03       Impact factor: 5.948

2.  Performance of two resin-containing blood culture media in detection of bloodstream infections and in direct matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) broth assays for isolate identification: clinical comparison of the BacT/Alert Plus and Bactec Plus systems.

Authors:  Barbara Fiori; Tiziana D'Inzeo; Viviana Di Florio; Flavio De Maio; Giulia De Angelis; Alessia Giaquinto; Lara Campana; Eloisa Tanzarella; Mario Tumbarello; Massimo Antonelli; Maurizio Sanguinetti; Teresa Spanu
Journal:  J Clin Microbiol       Date:  2014-07-16       Impact factor: 5.948

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.