Literature DB >> 15996513

High selective determination iron(II) by its enhancement effect on the fluorescence of pyrene-tetramethylpiperidinyl (TEMPO) as a spin fluorescence probe.

Jin-Long Chen1, Shu-Juan Zhuo, Yu-Qing Wu, Fang Fang, Ling Li, Chang-Qing Zhu.   

Abstract

A novel fluorescence method determination for iron(II) with a high selectivity and sensitivity has been proposed, based on the enhancement of fluorescence signals resulting from specific redox reaction between synthesized spin fluorescence probe pyrene-tetramethylpiperidinyl (TEMPO) and iron(II). Under the experimental conditions, fluorescent probe displayed a rapid and linear response for iron(II) over the concentration range from 2.4 x 10(-7) to 3.6 x 10(-6) mol/L. The limit of detection was 4.0 x 10(-8) mol/L. The relative standard deviation of six replicate measurements was 1.90% for 3.0 x 10(-7) mol/L iron(II). Because of the specific redox reaction between developed spin fluorescence probe and iron(II), there are few interference by other ions, especially in the presence of relative high concentration iron(III). The method has been successfully applied for iron(II) determinations in two different kinds of real samples. Results determined by the proposed method agree favorably with those determined UV-vis spectrometry method with 1,10-phenanthroline.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15996513     DOI: 10.1016/j.saa.2005.04.057

Source DB:  PubMed          Journal:  Spectrochim Acta A Mol Biomol Spectrosc        ISSN: 1386-1425            Impact factor:   4.098


  7 in total

Review 1.  Fluorescent sensors for measuring metal ions in living systems.

Authors:  Kyle P Carter; Alexandra M Young; Amy E Palmer
Journal:  Chem Rev       Date:  2014-03-03       Impact factor: 60.622

Review 2.  Analytical Methods for Imaging Metals in Biology: From Transition Metal Metabolism to Transition Metal Signaling.

Authors:  Cheri M Ackerman; Sumin Lee; Christopher J Chang
Journal:  Anal Chem       Date:  2016-12-15       Impact factor: 6.986

Review 3.  DNA as sensors and imaging agents for metal ions.

Authors:  Yu Xiang; Yi Lu
Journal:  Inorg Chem       Date:  2013-12-20       Impact factor: 5.165

4.  Flow injection spectrofluorimetric determination of iron in industrial effluents based on fluorescence quenching of 1-naphthol-2- sulfonate.

Authors:  Hossam E M Sayour; Taha M A Razek; Karima F Fadel
Journal:  J Fluoresc       Date:  2011-01-20       Impact factor: 2.217

5.  Probing oxidative stress: Small molecule fluorescent sensors of metal ions, reactive oxygen species, and thiols.

Authors:  Lynne M Hyman; Katherine J Franz
Journal:  Coord Chem Rev       Date:  2012-10-01       Impact factor: 22.315

6.  X-ray structures of precursors of styrylpyridine-derivatives used to obtain 4-((E)-2-(pyridin-2-yl)vinyl)benzamido-TEMPO: synthesis and characterization.

Authors:  Guillermo Soriano-Moro; María Judith Percino; Ana Laura Sánchez; Víctor Manuel Chapela; Margarita Cerón; María Eugenia Castro
Journal:  Molecules       Date:  2015-04-02       Impact factor: 4.411

7.  A facile colorimetric method for the quantification of labile iron pool and total iron in cells and tissue specimens.

Authors:  Usama Abbasi; Srinivas Abbina; Arshdeep Gill; Vriti Bhagat; Jayachandran N Kizhakkedathu
Journal:  Sci Rep       Date:  2021-03-16       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.