Literature DB >> 15995087

Exhaled nitric oxide levels during acute asthma exacerbation.

Michelle Gill1, Scott Walker, Aqeel Khan, Steven M Green, Lillian Kim, Shaun Gray, Baruch Krauss.   

Abstract

OBJECTIVES: Fractional exhaled nitric oxide (FE(NO)) has been shown in laboratory settings and trials of patients with stable asthma to correlate with the degree of airway inflammation. The authors hypothesized that the technique of measuring FE(NO) would be reproducible in the setting of acute asthma in the emergency department (ED) and that the FE(NO) results during ED visits would potentially predict disposition, predict relapse following discharge, and correlate with the National Institutes of Health (NIH) asthma severity scale and peak expiratory flow measurements.
METHODS: The authors prospectively measured FE(NO) in a convenience sample of ED patients with acute exacerbations of asthma, both at the earliest possible opportunity and then one hour later. Each assessment point included triplicate measurements to assess reproducibility. The authors also performed spirometry and classified asthma severity using the NIH asthma severity scale. Discharged patients were contacted in 72 hours to determine whether their asthma had relapsed.
RESULTS: The authors discontinued the trial (n = 53) after a planned interim analysis demonstrated reproducibility (coefficient of variation, 15%) substantially worse than our a priori threshold for precision (4%). There was no association between FE(NO) response and corresponding changes in spirometry or clinical scores. Areas under the receiver operating characteristic curves for the prediction of hospitalization and relapse were poor (0.579 and 0.713, respectively).
CONCLUSIONS: FE(NO) measurements in ED patients with acute asthma exacerbations were poorly reproducible and did not correlate with standard measures of asthma severity. These results suggest that using existing technology, FE(NO) is not a useful marker for assessing severity, response to treatment, or disposition of acute asthmatic patients in the ED.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15995087     DOI: 10.1197/j.aem.2005.01.018

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  7 in total

1.  Exhaled nitric oxide levels during treatment of pediatric acute asthma exacerbations and association with the need for hospitalization.

Authors:  Kyle A Nelson; Pearlene Lee; Kathryn Trinkaus; Robert C Strunk
Journal:  Pediatr Emerg Care       Date:  2011-04       Impact factor: 1.454

2.  Exhaled nitric oxide in wheezy infants: a marker of inflammation determined by airways acidification and S-nitrosothiol degradation?

Authors:  W Gerald Teague
Journal:  J Allergy Clin Immunol       Date:  2010-06       Impact factor: 10.793

3.  Are exhaled nitric oxide measurements using the portable NIOX MINO repeatable?

Authors:  Anna Selby; Bernie Clayton; Jane Grundy; Katy Pike; Kirsty Drew; Abid Raza; Ramesh Kurukulaaratchy; S Hasan Arshad; Graham Roberts
Journal:  Respir Res       Date:  2010-04-23

Review 4.  2020 Focused Updates to the Asthma Management Guidelines: A Report from the National Asthma Education and Prevention Program Coordinating Committee Expert Panel Working Group.

Authors:  Michelle M Cloutier; Alan P Baptist; Kathryn V Blake; Edward G Brooks; Tyra Bryant-Stephens; Emily DiMango; Anne E Dixon; Kurtis S Elward; Tina Hartert; Jerry A Krishnan; Robert F Lemanske; Daniel R Ouellette; Wilson D Pace; Michael Schatz; Neil S Skolnik; James W Stout; Stephen J Teach; Craig A Umscheid; Colin G Walsh
Journal:  J Allergy Clin Immunol       Date:  2020-12       Impact factor: 10.793

5.  Variability in airway inflammation, symptoms, lung function and reliever use in asthma: anti-inflammatory reliever hypothesis and STIFLE study design.

Authors:  Tim Harrison; Ian D Pavord; James D Chalmers; Glenn Whelan; Malin Fagerås; Annika Rutgersson; Laura Belton; Shahid Siddiqui; Per Gustafson
Journal:  ERJ Open Res       Date:  2020-06-08

6.  Hybrid Carbon Nanotubes/Gold Nanoparticles Composites for Trace Nitric Oxide Detection over a Wide Range of Humidity.

Authors:  Ami Hannon; Wayne Seames; Jing Li
Journal:  Sensors (Basel)       Date:  2022-10-06       Impact factor: 3.847

7.  Silicon nanowire-based devices for gas-phase sensing.

Authors:  Anping Cao; Ernst J R Sudhölter; Louis C P M de Smet
Journal:  Sensors (Basel)       Date:  2013-12-24       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.