Literature DB >> 15993778

Tricuspid regurgitation after cardiac transplantation: how many biopsies are too many?

Viviane Nguyen1, Marcelo Cantarovich, Renzo Cecere, Nadia Giannetti.   

Abstract

BACKGROUND: Tricuspid regurgitation (TR) is common in patients after orthotopic cardiac transplantation (OHT). Endomyocardial biopsy (EMB) used to monitor for rejection may be a cause of TR. The purpose of this study was to identify a correlation between the severity of TR and the number of EMBs.
METHODS: We studied 101 patients with OHT at our institution between May 1987 and August 2001. The number of EMBs performed in each patient was determined. Data on technique of anastomosis, liver and renal function, ejection fraction, and pulmonary artery pressure were also extracted. Echocardiography reports were reviewed to determine the presence and severity of TR. Symptoms of right heart failure were assessed by the amount of diuretic intake.
RESULTS: Twenty-five (25%) of 101 patients had evidence of severe TR, whereas 76 (75%) had non-severe TR. Multivariate analysis identified EMB as the only independent predictor of the severity of TR (p < 0.0001). At last follow-up, 60% of patients with more than 31 EMBs had developed severe TR, whereas none of the patients with less than 18 EMBs had severe TR. Of the 25 patients who had severe TR, 15 (61%) needed high doses of daily diuretics, and 4 (16%) required tricuspid valve replacement.
CONCLUSIONS: The development of TR after OHT is in large part due to EMBs used to monitor for rejection. There is a direct correlation between the number of EMBs and the severity of TR. We suggest a cutoff of less than 31 EMBs to reduce the risk of severe TR.

Entities:  

Mesh:

Year:  2005        PMID: 15993778     DOI: 10.1016/j.healun.2004.07.007

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  14 in total

1.  Complications of 2-D echocardiography guided transfemoral right ventricular endomyocardial biopsy.

Authors:  Juyup Han; Yongwhi Park; Hyunsang Lee; Hyunjae Kang; Hyungseop Kim; Dong Heon Yang; Hun Sik Park; Yongkeun Cho; Shung-Chull Chae; Jae-Eun Jun; Wee-Hyun Park
Journal:  J Korean Med Sci       Date:  2006-12       Impact factor: 2.153

2.  Endomyocardial biopsy for monitoring heart transplant patients: 11-years-experience at a german heart center.

Authors:  Thomas Strecker; Johannes Rösch; Michael Weyand; Abbas Agaimy
Journal:  Int J Clin Exp Pathol       Date:  2012-11-20

3.  Endomyocardial biopsy and selective coronary angiography are low-risk procedures in pediatric heart transplant recipients: results of a multicenter experience.

Authors:  Kevin P Daly; Audrey C Marshall; Julie A Vincent; Warren A Zuckerman; Timothy M Hoffman; Charles E Canter; Elizabeth D Blume; Lisa Bergersen
Journal:  J Heart Lung Transplant       Date:  2011-12-30       Impact factor: 10.247

Review 4.  Current status of endomyocardial biopsy.

Authors:  Aaron M From; Joseph J Maleszewski; Charanjit S Rihal
Journal:  Mayo Clin Proc       Date:  2011-11       Impact factor: 7.616

5.  Tricuspid valve regurgitation after heart transplantation.

Authors:  Murray H Kwon; Richard J Shemin
Journal:  Ann Cardiothorac Surg       Date:  2017-05

Review 6.  Multi-modal imaging of the pediatric heart transplant recipient.

Authors:  Jonathan H Soslow; Margaret M Samyn
Journal:  Transl Pediatr       Date:  2019-10

7.  Modified inferior vena caval anastomosis to reduce tricuspid valve regurgitation after heart transplantation.

Authors:  Daniel Marelli; Scott C Silvestry; Donna Zwas; Paul Mather; Sharon Rubin; Anthony F Dempsey; Louis Stein; Evelio Rodriguez; James T Diehl; Arthur M Feldman
Journal:  Tex Heart Inst J       Date:  2007

8.  Speckle-tracking 2-dimensional strain echocardiography: a new noninvasive imaging tool to evaluate acute rejection in cardiac transplantation.

Authors:  Galen M Pieper; Akash Shah; Leanne Harmann; Brian C Cooley; Irina A Ionova; Raymond Q Migrino
Journal:  J Heart Lung Transplant       Date:  2010-05-20       Impact factor: 13.569

9.  Tricuspid valve regurgitation after orthotopic heart transplantation: prevalence and etiology.

Authors:  Yaniv Berger; Yedael Har Zahav; Yigal Kassif; Alexander Kogan; Rafael Kuperstein; Dov Freimark; Jacob Lavee
Journal:  J Transplant       Date:  2012-10-14

Review 10.  Usefulness and limitations of transthoracic echocardiography in heart transplantation recipients.

Authors:  Sergio Mondillo; Massimo Maccherini; Maurizio Galderisi
Journal:  Cardiovasc Ultrasound       Date:  2008-01-11       Impact factor: 2.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.