Literature DB >> 15990666

Anatomic considerations for the pedicle screw placement in the first cervical vertebra.

Xiang-Yang Ma1, Qing-Shui Yin, Zeng-Hui Wu, Hong Xia, Jing-Fa Liu, Shi-Zhen Zhong.   

Abstract

STUDY
DESIGN: Anatomic bony measurements were manually performed on 50 dry atlantoaxial vertebral complexes with an electronic digital caliper, and a reliable landmark for insertion of a pedicle screw in C1 vertebra was described and evaluated.
OBJECTIVES: To investigate the feasibility of placing a screw in the C1 pedicle and evaluate the reliability of the C2 lateral mass as a landmark for determining the optimal site of screw entry. SUMMARY OF BACKGROUND DATA: The use of C1-C2 pedicle screws with the additional rods or plates has been an alternative method of stabilization for patients who are unsuitable for C1-C2 transarticular screw stabilization. However, the optimal portal of entry for the C1 pedicle screw is difficult to determine during surgery in the absence of reliable reference landmarks and sufficient relevant anatomic studies.
METHODS: We manually measured 11 linear anatomic parameters related to the C1 lateral mass, its pedicle and posterior arch under the groove on 50 pairs of dry C1-C2 complexes harvested from cadavers. We also treated five patients with atlantoaxial instability with C1 and C2 pedicle screw fixation; the entry point of the C1 pedicle screw was ascertained by using C2 lateral mass as a landmark, and the position of the C1 pedicle screws in each case was evaluated with postoperative radiographs and computed tomography scans.
RESULTS: The mean mediolateral width and rostrocaudal height of C1 pedicle were 8.57 and 5.83 mm, respectively. The mean rostrocaudal height of C1 posterior lamina at the reference entry point for the screw was 4.59 mm. The mean rostrocaudal height of the C1 posterior arch under the vertebral artery groove was 3.88 mm at its medial one-third and 4.25 mm at its lateral one-third. The thinnest external diameter of the screw tract that was recorded was <4 mm in six (12%) specimens of C1 vertebrae. The center of C2 lateral mass was 1.51 mm lateral to the sagittal plane of the mediolateral midpoint of the C1 pedicle. The distance from the suggested screw entry point to C1 posterior tubercle was 22.15 mm, and the mean length of the screw tract was 28.55 mm. Ten C1 pedicle screws were placed exactly, without neural or vascular injury in all five patients.
CONCLUSION: The heights of the C1 pedicle, the posterior arch under the groove and the posterior lamina at the screw entry point are the major determinants for the possibility of placing pedicle screws in C1 of a given patient. This study indicates that it is feasible to place a 3.5-mm pedicle screw safely in C1 in most patients, and the lateral mass of C2 is a reliable anatomic landmark that can be easily identified to help the surgeon determine the optimal screw entry portal conveniently during surgery.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15990666     DOI: 10.1097/01.brs.0000168546.17788.49

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  31 in total

1.  Comparison of perpendicular to the coronal plane versus medial inclination for atlas pedicle screw insertion: an anatomic and radiological study in human cadavers.

Authors:  Jun Ma; Jian Tang; Deguang Wang; Yucheng Zhu; Tao Sui; Xiaojian Cao
Journal:  Int Orthop       Date:  2015-08-15       Impact factor: 3.075

2.  Prevalence and Morphologic Characteristics of Ponticulus Posticus: Analysis Using Cone-Beam Computed Tomography.

Authors:  Ahmet Ercan Sekerci; Emrah Soylu; Mehtap Payveren Arikan; Gozde Ozcan; Mehmet Amuk; Fatma Kocoglu
Journal:  J Chiropr Med       Date:  2015-11-05

3.  Anterior retropharyngeal fixation C1-2 for stabilization of atlantoaxial instabilities: study of feasibility, technical description and preliminary results.

Authors:  Heiko Koller; Volker Kammermeier; Dietmar Ulbricht; Allan Assuncao; Stefan Karolus; Boris van den Berg; Ulrich Holz
Journal:  Eur Spine J       Date:  2006-04-08       Impact factor: 3.134

4.  Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws: a cadaveric study.

Authors:  Florian Fensky; Rebecca A Kueny; Kay Sellenschloh; Klaus Püschel; Michael M Morlock; Johannes M Rueger; Wolfgang Lehmann; Gerd Huber; Nils Hansen-Algenstaedt
Journal:  Eur Spine J       Date:  2013-12-31       Impact factor: 3.134

5.  Novel unilateral C1 double screw and ipsilateral C2 pedicle screw placement combined with contralateral laminar screw-rod fixation for atlantoaxial instability.

Authors:  Lei Shi; Kai Shen; Rui Deng; Zheng-Jian Yan; Kai-Lu Liang; Liang Chen; Zhen-Yong Ke; Zhong-Liang Deng
Journal:  Eur Spine J       Date:  2018-12-11       Impact factor: 3.134

6.  Cadaveric morphometric anatomy of C-1 vertebra in relation to lateral mass screw placement.

Authors:  Tulika Gupta
Journal:  Surg Radiol Anat       Date:  2008-06-25       Impact factor: 1.246

7.  Evaluation of anatomic landmarks and safe zones for screw placement in the atlas via the posterior arch.

Authors:  Matthias Gebauer; Florian Barvencik; Daniel Briem; Jan P Kolb; Sebastian Seitz; Johannes M Rueger; Klaus Püschel; Michael Amling
Journal:  Eur Spine J       Date:  2009-10-31       Impact factor: 3.134

8.  Atlas posterior arch and vertebral artery's groove variants: a classification, morphometric study, clinical and surgical implications.

Authors:  Konstantinos Natsis; Evangelia-Theophano Piperaki; Moschos Fratzoglou; Nikolaos Lazaridis; Parmenion P Tsitsopoulos; Αlexandros Samolis; Michael Kostares; Maria Piagkou
Journal:  Surg Radiol Anat       Date:  2019-06-06       Impact factor: 1.246

9.  Morphology of the atlas pedicle revisited: a morphometric CT-based study on 120 patients.

Authors:  Li-Xiong Qian; Ding-Jun Hao; Bao-Rong He; Yong-Hong Jiang
Journal:  Eur Spine J       Date:  2013-01-29       Impact factor: 3.134

10.  Prevalence and Morphologic Features of Ponticulus Posticus in Koreans: Analysis of 312 Radiographs and 225 Three-dimensional CT Scans.

Authors:  Kyeong Hwan Kim; Kun Woo Park; Tran Hoang Manh; Jin Sup Yeom; Bong-Soon Chang; Choon-Ki Lee
Journal:  Asian Spine J       Date:  2007-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.