Literature DB >> 15986155

Traceability in fluorometry--Part I: Physical standards.

J Hollandt1, R D Taubert, J Seidel, U Resch-Genger, A Gugg-Helminger, D Pfeifer, C Monte, W Pilz.   

Abstract

The inter-instrument, inter-laboratory, and long-term comparability of fluorescence data requires the correction of the measured emission and excitation spectra for the wavelength- and polarization-dependent spectral irradiance of the excitation channel at the sample position and the spectral responsivity of the emission channel employing procedures that guarantee traceability to the respective primary standards. In this respect the traceability chain of fluorometry is discussed from a radiometrist's point of view. This involves, in a first step, the realization of the spectral radiance scale, based on the blackbody radiator and electron storage ring, and the spectral responsivity scale, based on the cryogenic radiometer and their control via key comparisons of the national metrology institutes. In a second step, the characterization including state-of-the art uncertainties of the respective source and detector transfer standards such as tungsten strip lamps, integrating sphere radiators, and trap detectors used to disseminate these radiometric quantities to users of spectroscopic techniques is presented.

Entities:  

Year:  2005        PMID: 15986155     DOI: 10.1007/s10895-005-2628-x

Source DB:  PubMed          Journal:  J Fluoresc        ISSN: 1053-0509            Impact factor:   2.217


  4 in total

1.  How to improve quality assurance in fluorometry: fluorescence-inherent sources of error and suited fluorescence standards.

Authors:  U Resch-Genger; K Hoffmann; W Nietfeld; A Engel; J Neukammer; R Nitschke; B Ebert; R Macdonald
Journal:  J Fluoresc       Date:  2005-05       Impact factor: 2.217

2.  Traceability in fluorometry: Part II. Spectral fluorescence standards.

Authors:  U Resch-Genger; D Pfeifer; C Monte; W Pilz; A Hoffmann; M Spieles; K Rurack; J Hollandt; D Taubert; B Schönenberger; P Nording
Journal:  J Fluoresc       Date:  2005-05       Impact factor: 2.217

3.  The Calibration Kit Spectral Fluorescence Standards--a simple and certified tool for the standardization of the spectral characteristics of fluorescence instruments.

Authors:  D Pfeifer; K Hoffmann; A Hoffmann; C Monte; U Resch-Genger
Journal:  J Fluoresc       Date:  2006-06-22       Impact factor: 2.217

4.  Relative and absolute determination of fluorescence quantum yields of transparent samples.

Authors:  Christian Würth; Markus Grabolle; Jutta Pauli; Monika Spieles; Ute Resch-Genger
Journal:  Nat Protoc       Date:  2013-07-18       Impact factor: 13.491

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.