Accounting for beta-particle energy loss to cortical bone via paired-image radiation transport (PIRT).

Amish P Shah1, Didier A Rajon, Phillip W Patton, Derek W Jokisch, Wesley E Bolch.   

Abstract

Current methods of skeletal dose assessment in both medical physics (radionuclide therapy) and health physics (dose reconstruction and risk assessment) rely heavily on a single set of bone and marrow cavity chord-length distributions in which particle energy deposition is tracked within an infinite extent of trabecular spongiosa, with no allowance for particle escape to cortical bone. In the present study, we introduce a paired-image radiation transport (PIRT) model which provides a more realistic three-dimensional (3D) geometry for particle transport in the skeletal site at both microscopic and macroscopic levels of its histology. Ex vivo CT scans were acquired of the pelvis, cranial cap, and individual ribs excised from a 66-year male cadaver (BMI of 22.7 kg m(-2)). For the three skeletal sites, regions of trabecular spongiosa and cortical bone were identified and segmented. Physical sections of interior spongiosa were taken and subjected to microCT imaging. Voxels within the resulting microCT images were then segmented and labeled as regions of bone trabeculae, endosteum, active marrow, and inactive marrow through application of image processing algorithms. The PIRT methodology was then implemented within the EGSNRC radiation transport code whereby electrons of various initial energies are simultaneously tracked within both the ex vivo CT macroimage and the CT microimage of the skeletal site. At initial electron energies greater than 50-200 keV, a divergence in absorbed fractions to active marrow are noted between PIRT model simulations and those estimated under existing techniques of infinite spongiosa transport. Calculations of radionuclide S values under both methodologies imply that current chord-based models may overestimate the absorbed dose to active bone marrow in these skeletal sites by 0% to 27% for low-energy beta emitters (33P, 169Er, and 177Lu), by approximately 4% to 49% for intermediate-energy beta emitters (153Sm, 186Re, and 89Sr), and by approximately 14% to 76% for high-energy beta emitters (32p, 188Re, and 90Y). The PIRT methodology allows for detailed modeling of the 3D macrostructure of individual marrow-containing bones within the skeleton thus permitting improved estimates of absorbed fractions and radionuclide S values for intermediate-to-high energy beta emitters.

Mesh:

Year:  2005        PMID: 15984687     DOI: 10.1118/1.1898463

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  MIRD Pamphlet No. 22 (abridged): radiobiology and dosimetry of alpha-particle emitters for targeted radionuclide therapy.

Authors:  George Sgouros; John C Roeske; Michael R McDevitt; Stig Palm; Barry J Allen; Darrell R Fisher; A Bertrand Brill; Hong Song; Roger W Howell; Gamal Akabani; Wesley E Bolch; A Bertrand Brill; Darrell R Fisher; Roger W Howell; Ruby F Meredith; George Sgouros; Barry W Wessels; Pat B Zanzonico
Journal:  J Nucl Med       Date:  2010-01-15       Impact factor: 10.057

2.  A study of predicted bone marrow distribution on calculated marrow dose from external radiation exposures using two sets of image data for the same individual.

Authors:  Peter F Caracappa; T C Ephraim Chao; X George Xu
Journal:  Health Phys       Date:  2009-06       Impact factor: 1.316

3.  An image-based skeletal dosimetry model for the ICRP reference adult female-internal electron sources.

Authors:  Shannon E O'Reilly; Lindsay S DeWeese; Matthew R Maynard; Didier A Rajon; Michael B Wayson; Emily L Marshall; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2016-11-29       Impact factor: 3.609