Literature DB >> 15975460

One or 2 Intacs segments for the correction of keratoconus.

Jorge L Alió1, Alberto Artola, Ahmed Hassanein, Hazem Haroun, Ahmed Galal.   

Abstract

PURPOSE: To evaluate the effect of implanting 1 or 2 intracorneal rings (Intacs, KeraVision) as a device to correct, stabilize, and/or improve the best corrected visual acuity in patients with clear cornea keratoconus oriented by the preoperative corneal topography pattern.
SETTING: Vissum/Instituto Oftalmológico de Alicante, Miguel Hernandez University, Alicante, Spain.
METHODS: In this prospective comparative consecutive study, Intacs segments were implanted in 26 keratoconic eyes with clear central corneas of 19 consecutive patients (9 women and 10 men). Corneas were divided into 2 groups according to the topographic pattern of the cone. Group I included keratoconus not crossing the 180 degrees meridian and Group II included keratoconus crossing the 180 degrees meridian. The Intacs were horizontally placed through a lateral clear corneal incision. According to the corneal topography 1 segment was implanted 0.45 mm inferior in Group I, and 2 segments were implanted, 1 0.25 mm superior and the other 0.45 mm inferior, in Group II. All cases completed a minimum follow-up of 1 year. Differences between preoperative and postoperative uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, and keratometry were clinically and statistically evaluated.
RESULTS: Spherical equivalent error and refractive astigmatism were significantly reduced. The mean keratometric values were reduced following Intacs insertion in both groups. At the end of the first year of the postoperative follow-up, Group I (1 segment) had an improvement in mean UCVA to 20/50 (0.4 +/- 0.22 decimal value), which was statistically significant when compared to the preoperative UCVA of 20/100 (0.2 +/- 0.13 decimal value) (P=.011). Mean BSCVA was 20/32 (0.62 +/- 0.24 decimal value), which was also statistically significant when compared to the preoperative BSCVA, which was 20/50 (0.4 +/- 0.21 decimal value) (P=.002). In Group II (2 segments), UCVA after 1 year was 20/63 (0.34 +/- 0.17 decimal value), which was statistically significant when compared to the preoperative UCVA of 20/400 (0.06 +/- 0.02 decimal value) (P=.001). Mean BSCVA was 20/32 (0.62 +/- 0.27 decimal value), which was significantly better than the preoperative UCVA of 20/50 (0.38 +/- 0.22 decimal value) (P=.001). In 4 eyes, the inferior segment was removed because of partial extrusion during the postoperative follow-up.
CONCLUSIONS: Treatment of keratoconus with 1 or 2 Intacs segments oriented by the preoperative corneal topography used in this study proved to be effective in decreasing the corneal steepening and astigmatism and improving BSCVA. Further follow-up is needed to determine the final effect of Intacs on the progression of the corneal disease.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15975460     DOI: 10.1016/j.jcrs.2004.09.050

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  21 in total

Review 1.  INTACS for keratoconus.

Authors:  Yaron S Rabinowitz
Journal:  Int Ophthalmol Clin       Date:  2006

2.  [Aberration corrected intraocular lens for microincision cataract surgery (MICS). Intraindividual comparison with a conventional lens - 1-year follow-up].

Authors:  M Möglich; H Häberle; D T Pham; C Wirbelauer
Journal:  Ophthalmologe       Date:  2009-10       Impact factor: 1.059

3.  Treatment of moderate to severe keratoconus with 6-mm Intacs SK.

Authors:  Sasan Niknam; Mehrdad Shamshiri; Seyed Sahabaldin Shahrzad; Abbas Alipour; Mohammad Bagher Rajabi; Mohammad Taher Rajabi
Journal:  Int J Ophthalmol       Date:  2012-08-18       Impact factor: 1.779

4.  Clinical evaluation of two types of intracorneal ring segments (ICRS) for keratoconus.

Authors:  Waleed S Al-Tuwairqi; Uchechukwu L Osuagwu; Haya Razzouk; Ahmed AlHarbi; Kelechi C Ogbuehi
Journal:  Int Ophthalmol       Date:  2016-11-01       Impact factor: 2.031

5.  Mathematical analysis of corneal remodelling after intracorneal ring surgery in keratoconus.

Authors:  Elias F Jarade; Elise Slim; Carole Cherfan; Hala El Rami; Toufic Hassan; Elias Chelala
Journal:  Int J Ophthalmol       Date:  2017-03-18       Impact factor: 1.779

Review 6.  INTACS for keratoconus and ectasia after LASIK.

Authors:  Yaron S Rabinowitz
Journal:  Int Ophthalmol Clin       Date:  2013

7.  Keratoconus: overview and update on treatment.

Authors:  Ladan Espandar; Jay Meyer
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01

8.  Intrastromal corneal ring implants for corneal thinning disorders: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2009-04-01

Review 9.  Pediatric keratoconus: a review of the literature.

Authors:  Sabrina Mukhtar; Balamurali K Ambati
Journal:  Int Ophthalmol       Date:  2017-08-29       Impact factor: 2.031

Review 10.  Clinical and research applications of anterior segment optical coherence tomography - a review.

Authors:  Jose Luiz Branco Ramos; Yan Li; David Huang
Journal:  Clin Exp Ophthalmol       Date:  2008-11-05       Impact factor: 4.207

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.