Literature DB >> 15972974

Absorption spectra variations of EBT radiochromic film from radiation exposure.

M J Butson1, T Cheung, P K N Yu.   

Abstract

Gafchromic EBT radiochromic film is one of the newest radiation-induced auto-developing x-ray analysis films available for therapeutic radiation dosimetry in radiotherapy applications. The spectral absorption properties in the visible wavelengths have been investigated and results show two main peaks in absorption located at 636 nm and 585 nm. These absorption peaks are different to many other radiochromic film products such as Gafchromic MD-55 and HS film where two peaks were located at 676 nm and 617 nm respectively. The general shape of the absorption spectra is similar to older designs. A much higher sensitivity is found at high-energy x-rays with an average 0.6 OD per Gy variation in OD seen within the first Gy measured at 636 nm using 6 MV x-rays. This is compared to approximately 0.09 OD units for the first Gy at the 676 nm absorption peak for HS film at 6 MV x-ray energy. The film's blue colour is visually different from older varieties of Gafchromic film with a higher intensity of mid-range blue within the film. The film provides adequate relative absorbed dose measurement for clinical radiotherapy x-ray assessment in the 1-2 Gy dose range which with further investigation may be useful for fractionated radiotherapy dose assessment.

Entities:  

Mesh:

Year:  2005        PMID: 15972974     DOI: 10.1088/0031-9155/50/13/N02

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  Energy dependence of radiochromic dosimetry films for use in radiotherapy verification.

Authors:  Krzysztof Chełmiński; Wojciech Bulski; Dietmar Georg; Dominika Bodzak; Zbigniew Maniakowski; Dominika Oborska; Joanna Rostkowska; Małgorzata Kania
Journal:  Rep Pract Oncol Radiother       Date:  2010-03-30

2.  Simulation for improvement of system sensitivity of radiochromic film dosimetry with different band-pass filters and scanner light intensities.

Authors:  Takeshi Kamomae; Yuki Miyabe; Akira Sawada; Osamu Matoba; Manabu Nakata; Shinsuke Yano; Toru Takakura; Takashi Mizowaki; Akio Itoh; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2011-03-17

3.  Characterization of a 137Cs irradiator from a new perspective with modern dosimetric tools.

Authors:  Samuel L Brady; Greta Toncheva; Mark W Dewhirst; Terry T Yoshizumi
Journal:  Health Phys       Date:  2009-09       Impact factor: 1.316

4.  Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small-field animal irradiation studies.

Authors:  Noora Ba Sunbul; Ibrahim Oraiqat; Benjamin Rosen; Cameron Miller; Christopher Meert; Martha M Matuszak; Shaun Clarke; Sara Pozzi; Jean M Moran; Issam El Naqa
Journal:  Med Phys       Date:  2021-02-06       Impact factor: 4.071

5.  Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms.

Authors:  Barbara Dobler; Cornelia Walter; Antje Knopf; Daniella Fabri; Rainer Loeschel; Martin Polednik; Frank Schneider; Frederik Wenz; Frank Lohr
Journal:  Radiat Oncol       Date:  2006-11-29       Impact factor: 3.481

6.  Commissioning of a double-focused micro multileaf collimator (muMLC).

Authors:  Marcus Fischer; Manuel Todorovic; Eva Drud; Florian Cremers
Journal:  J Appl Clin Med Phys       Date:  2010-04-16       Impact factor: 2.102

7.  A light field-based method to adjust rounded leaf end MLC position for split shape dose calculation correction in a radiation therapy treatment planning system.

Authors:  Jia-Ming Wu; Tsair-Fwu Lee; Chung-Ming Kuo; Ching-Jiang Chen; Shyh-An Yeh
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

8.  In vivo optical imaging of tumor and microvascular response to ionizing radiation.

Authors:  Azusa Maeda; Michael K K Leung; Leigh Conroy; Yonghong Chen; Jiachuan Bu; Patricia E Lindsay; Shani Mintzberg; Carl Virtanen; Julissa Tsao; Neil A Winegarden; Yanchun Wang; Lily Morikawa; I Alex Vitkin; David A Jaffray; Richard P Hill; Ralph S DaCosta
Journal:  PLoS One       Date:  2012-08-22       Impact factor: 3.240

9.  Build-up material requirements in clinical dosimetry during total body irradiation treatments.

Authors:  Martin Butson; Dane Pope; Mamoon Haque; Tom Chen; Guangli Song; May Whitaker
Journal:  J Med Phys       Date:  2016 Apr-Jun

10.  Radiation transmission, leakage and beam penumbra measurements of a micro-multileaf collimator using GafChromic EBT film.

Authors:  Olivia Amanda García-Garduño; Miguel Angel Celis; José Manuel Lárraga-Gutiérrez; Sergio Moreno-Jiménez; Arnulfo Martínez-Dávalos; Mercedes Rodríguez-Villafuerte
Journal:  J Appl Clin Med Phys       Date:  2008-06-23       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.