Abstract

A new automated method for quantification of left ventricular function from gated-single photon emission computed tomography (SPECT) images has been developed. The method for quantification of cardiac function (CAFU) is based on a heart shaped model and the active shape algorithm. The model contains statistical information of the variability of left ventricular shape. CAFU was adjusted based on the results from the analysis of five simulated gated-SPECT studies with well defined volumes of the left ventricle. The digital phantom NURBS-based Cardiac-Torso (NCAT) and the Monte-Carlo method SIMIND were used to simulate the studies. Finally CAFU was validated on ten rest studies from patients referred for routine stress/rest myocardial perfusion scintigraphy and compared with Cedar-Sinai quantitative gated-SPECT (QGS), a commercially available program for quantification of gated-SPECT images. The maximal differences between the CAFU estimations and the true left ventricular volumes of the digital phantoms were 11 ml for the end-diastolic volume (EDV), 3 ml for the end-systolic volume (ESV) and 3% for the ejection fraction (EF). The largest differences were seen in the smallest heart. In the patient group the EDV calculated using QGS and CAFU showed good agreement for large hearts and higher CAFU values compared with QGS for the smaller hearts. In the larger hearts, ESV was much larger for QGS than for CAFU both in the phantom and patient studies. In the smallest hearts there was good agreement between QGS and CAFU. The findings of this study indicate that our new automated method for quantification of gated-SPECT images can accurately measure left ventricular volumes and EF.

Entities:  

Mesh:

Year:  2005        PMID: 15972026     DOI: 10.1111/j.1475-097X.2005.00619.x

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  11 in total

1.  Use of neural networks to improve quality control of interpretations in myocardial perfusion imaging.

Authors:  K Tägil; J Marving; M Lomsky; B Hesse; L Edenbrandt
Journal:  Int J Cardiovasc Imaging       Date:  2008-06-29       Impact factor: 2.357

2.  Evaluation of a decision support system for interpretation of myocardial perfusion gated SPECT.

Authors:  Milan Lomsky; Peter Gjertsson; Lena Johansson; Jens Richter; Mattias Ohlsson; Deborah Tout; Andries van Aswegen; S Richard Underwood; Lars Edenbrandt
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-03-04       Impact factor: 9.236

3.  Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac magnetic resonance as reference standard.

Authors:  Helen Soneson; Fredrik Hedeer; Carmen Arévalo; Marcus Carlsson; Henrik Engblom; Joey F A Ubachs; Håkan Arheden; Einar Heiberg
Journal:  J Nucl Cardiol       Date:  2011-07-15       Impact factor: 5.952

4.  Reducing the small-heart effect in pediatric gated myocardial perfusion single-photon emission computed tomography.

Authors:  Hiroto Yoneyama; Kenichi Nakajima; Koichi Okuda; Shinro Matsuo; Masahisa Onoguchi; Seigo Kinuya; Lars Edenbrandt
Journal:  J Nucl Cardiol       Date:  2016-05-19       Impact factor: 5.952

5.  Ready, shoot, aim? Summary justice for small hearts in nuclear cardiology.

Authors:  Guido Germano; Paul B Kavanagh
Journal:  J Nucl Cardiol       Date:  2016-05-20       Impact factor: 5.952

6.  Gated myocardial perfusion SPECT underestimates left ventricular volumes and shows high variability compared to cardiac magnetic resonance imaging -- a comparison of four different commercial automated software packages.

Authors:  Fredrik Hedeer; John Palmer; Håkan Arheden; Martin Ugander
Journal:  BMC Med Imaging       Date:  2010-05-25       Impact factor: 1.930

7.  Automated quality control for segmentation of myocardial perfusion SPECT.

Authors:  Yuan Xu; Paul Kavanagh; Mathews Fish; James Gerlach; Amit Ramesh; Mark Lemley; Sean Hayes; Daniel S Berman; Guido Germano; Piotr J Slomka
Journal:  J Nucl Med       Date:  2009-08-18       Impact factor: 10.057

8.  A new automated method for analysis of rCBF-SPECT images based on the active-shape algorithm: normal values.

Authors:  Douglas Hägerström; David Jakobsson; Erik Stomrud; Ann-Margret Andersson; Erik Ryding; Elisabet Londos; Lennart Minthon; Ingmar Rosén; Lars Edenbrandt
Journal:  Clin Physiol Funct Imaging       Date:  2011-11-08       Impact factor: 2.273

9.  Improved quantification of small hearts for gated myocardial perfusion imaging.

Authors:  Kenichi Nakajima; Koichi Okuda; Karin Nyström; Jens Richter; David Minarik; Hiroshi Wakabayashi; Shinro Matsuo; Seigo Kinuya; Lars Edenbrandt
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-04-30       Impact factor: 9.236

10.  Normal limits for left ventricular ejection fraction and volumes determined by gated single photon emission computed tomography--a comparison between two quantification methods.

Authors:  Milan Lomsky; Lena Johansson; Peter Gjertsson; Jonas Björk; Lars Edenbrandt
Journal:  Clin Physiol Funct Imaging       Date:  2008-02-25       Impact factor: 2.273

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.