Literature DB >> 15960717

Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope.

C Rudolph1, J P Schneider, J Wallenborn, L Schaffranietz.   

Abstract

The movements of the upper cervical spine were measured by fluoroscopy in 20 patients during laryngoscopy with the Bonfils intubation fibrescope and the Macintosh laryngoscope. Laryngoscopy with both the Bonfils intubation fibrescope and the Macintosh laryngoscope resulted in significant extension of the cervical spine as compared to the neutral position but this extension was significantly less with the Bonfils intubation fibrescope than with the Macintosh (p = 0.001). However, the atlanto-occipital distance was significantly greater during laryngoscopy with the Bonfils intubation fibrescope (p = 0.002), and the angle between the occiput and C1 differed significantly between the two techniques (p = 0.001). With the Bonfils intubation fibrescope, significantly less extension was also found at the C1/C2 and C3/C4 levels (p = 0.001 and p = 0.049, respectively). There is therefore significantly less movement of the upper cervical spine during laryngoscopy with the Bonfils fibrescope compared with the Macintosh laryngoscope.

Entities:  

Mesh:

Year:  2005        PMID: 15960717     DOI: 10.1111/j.1365-2044.2005.04224.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  14 in total

1.  Awake tracheal intubation in a patient with a supraglottic mass with the Bonfils fibrescope after failed attempts with a flexible fibrescope.

Authors:  Geoffrey Liew; Xin Fang Leong; Theodore Wong
Journal:  Singapore Med J       Date:  2015-08       Impact factor: 1.858

Review 2.  [Indirect laryngoscopy : Alternatives to securing the airway].

Authors:  R R Noppens; C Werner; T Piepho
Journal:  Anaesthesist       Date:  2010-02       Impact factor: 1.041

Review 3.  Development of endotracheal intubation devices for patients with tumors.

Authors:  Yang Liu; Yang Zhang; Bin Zhu; Wenyun Xu; Yi Yang; Zui Zou
Journal:  Am J Cancer Res       Date:  2022-06-15       Impact factor: 5.942

4.  Fluoroscopic Comparison of Cervical Spine Motion Using LMA CTrach, C-MAC Videolaryngoscope and Macintosh Laryngoscope.

Authors:  Tülay Şahin; Zehra İpek Arslan; Gür Akansel; Onur Balaban; Derya Berk; Mine Solak; Kamil Toker
Journal:  Turk J Anaesthesiol Reanim       Date:  2018-02-01

5.  Awake intubation with Bonfil's retromolar fibroscope in a patient with hard and fixed swelling of the right side of the neck and the tonsillar tumor.

Authors:  Mamdouh Medhat; T Aljuhani
Journal:  Saudi J Anaesth       Date:  2011-10

6.  Neurological deterioration during intubation in cervical spine disorders.

Authors:  Padmaja Durga; Barada Prasad Sahu
Journal:  Indian J Anaesth       Date:  2014 Nov-Dec

7.  Bonfils intubation fibrescope: use in simulation-based intubation training for medical students in comparison to MacIntosh laryngoscope.

Authors:  Tobias Limbach; Thomas Ott; Jan Griesinger; Antje Jahn-Eimermacher; Tim Piepho
Journal:  BMC Res Notes       Date:  2016-02-27

8.  Rigid fibrescope Bonfils: use in simulated difficult airway by novices.

Authors:  Tim Piepho; Rüdiger R Noppens; Florian Heid; Christian Werner; Andreas R Thierbach
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2009-07-22       Impact factor: 2.953

9.  Comparison of the Airtraq and Truview laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins.

Authors:  Sajid Nasim; Chrisen H Maharaj; Ihsan Butt; Muhammad A Malik; John O' Donnell; Brendan D Higgins; Brian H Harte; John G Laffey
Journal:  BMC Emerg Med       Date:  2009-02-13

10.  Comparison of the Glidescope and Pentax AWS laryngoscopes to the Macintosh laryngoscope for use by advanced paramedics in easy and simulated difficult intubation.

Authors:  Sajid Nasim; Chrisen H Maharaj; Muhammad A Malik; John O' Donnell; Brendan D Higgins; John G Laffey
Journal:  BMC Emerg Med       Date:  2009-05-17
View more