Literature DB >> 15958239

Polyethylene oxide surfaces of variable chain density by chemisorption of PEO-thiol on gold: adsorption of proteins from plasma studied by radiolabelling and immunoblotting.

Larry D Unsworth1, Heather Sheardown, John L Brash.   

Abstract

The mechanisms involved in the inhibition of protein adsorption by polyethylene oxide (PEO) are not completely understood, but it is believed that PEO chain length, chain density and chain conformation all play a role. In this work, surfaces formed by chemisorption of PEO-thiol to gold were investigated: the effects of PEO chain density, chain length (600, 750, 2000 and 5000 MW) and end-group (-OH, -OCH3) on protein adsorption from plasma are reported. Similar to previous single protein adsorption studies (L.D. Unsworth et al., Langmuir 2005;21:1036-41) it was found that, of the different surfaces investigated, PEO layers formed from solutions near the cloud point adsorbed the lowest amount of fibrinogen from plasma. Layers of hydroxyl-terminated PEO of MW 600 formed under these low solubility conditions showed almost complete suppression (versus controls) of the Vroman effect, with 20+/-1 ng/cm2 adsorbed fibrinogen at the Vroman peak and 6.7+/-0.6 ng/cm2 at higher plasma concentration. By comparison, Vroman peak adsorption was 70+/-20 and 50+/-3 ng/cm2, respectively, for 750-OCH3 and 2000-OCH3 layers formed under low solubility conditions; adsorption on these surfaces at higher plasma concentration was 16+/-9 and 12+/-3 ng/cm2. Thus in addition to the effect of solution conditions noted previously, the results of this study also suggest a chain end group effect which inhibits fibrinogen adsorption to, and/or facilitates displacement from, hydroxyl terminated PEO layers. Fibrinogen adsorption from plasma was not significantly different for surfaces prepared with PEO of molecular weight 750 and 2000 when the chain density was the same ( approximately 0.5 chains/nm2) supporting the conclusion that chain density may be the key property for suppression of protein adsorption. The proteins eluted from the surfaces after contact with plasma were investigated by SDS-PAGE and immunoblotting. A number of proteins were detected on the various surfaces including fibrinogen, albumin, C3 and apolipoprotein A-I. The blot responses were zero or weak for all four proteins of the contact system; some complement activation was observed on all of the surfaces studied.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15958239     DOI: 10.1016/j.biomaterials.2005.03.010

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  15 in total

1.  Short-term and long-term effects of orthopedic biodegradable implants.

Authors:  Ami R Amini; James S Wallace; Syam P Nukavarapu
Journal:  J Long Term Eff Med Implants       Date:  2011

Review 2.  Engineering biomaterials to integrate and heal: the biocompatibility paradigm shifts.

Authors:  James D Bryers; Cecilia M Giachelli; Buddy D Ratner
Journal:  Biotechnol Bioeng       Date:  2012-05-24       Impact factor: 4.530

Review 3.  The blood compatibility challenge. Part 2: Protein adsorption phenomena governing blood reactivity.

Authors:  John L Brash; Thomas A Horbett; Robert A Latour; Pentti Tengvall
Journal:  Acta Biomater       Date:  2019-06-18       Impact factor: 8.947

4.  Anti-inflammatory polymeric coatings for implantable biomaterials and devices.

Authors:  Amanda W Bridges; Andrés J García
Journal:  J Diabetes Sci Technol       Date:  2008-11

5.  Mode of lysozyme protein adsorption at end-tethered polyethylene oxide brushes on gold surfaces determined by neutron reflectivity.

Authors:  Warren Taylor; Stephen Ebbens; Maximillian W A Skoda; John R P Webster; Richard A L Jones
Journal:  Eur Phys J E Soft Matter       Date:  2015-03-09       Impact factor: 1.890

6.  Application of MS-based proteomics to study serum protein adsorption/absorption and complement C3 activation on poly(ethylene glycol) hydrogels.

Authors:  Xintong Wang; David R Schmidt; Evan J Joyce; W John Kao
Journal:  J Biomater Sci Polym Ed       Date:  2011       Impact factor: 3.517

7.  Complement activation on poly(ethylene oxide)-like radiofrequency glow discharge-deposited surfaces.

Authors:  Luisa Mayorga Szott; M Jeanette Stein; Buddy D Ratner; Thomas A Horbett
Journal:  J Biomed Mater Res A       Date:  2010-11-05       Impact factor: 4.396

8.  Nonfouling poly(ethylene oxide) layers end-tethered to polydopamine.

Authors:  Ognen Pop-Georgievski; Dominique Verreault; Mark-Oliver Diesner; Vladimír Proks; Stefan Heissler; František Rypáček; Patrick Koelsch
Journal:  Langmuir       Date:  2012-09-28       Impact factor: 3.882

9.  An omniphobic lubricant-infused coating produced by chemical vapor deposition of hydrophobic organosilanes attenuates clotting on catheter surfaces.

Authors:  Maryam Badv; Iqbal H Jaffer; Jeffrey I Weitz; Tohid F Didar
Journal:  Sci Rep       Date:  2017-09-14       Impact factor: 4.379

10.  BSA Nanoparticles for siRNA Delivery: Coating Effects on Nanoparticle Properties, Plasma Protein Adsorption, and In Vitro siRNA Delivery.

Authors:  Haran Yogasundaram; Markian Stephan Bahniuk; Harsh-Deep Singh; Hamidreza Montezari Aliabadi; Hasan Uludağ; Larry David Unsworth
Journal:  Int J Biomater       Date:  2012-08-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.