Literature DB >> 15958213

Cardiovascular stent design and vessel stresses: a finite element analysis.

C Lally1, F Dolan, P J Prendergast.   

Abstract

Intravascular stents of various designs are currently in use to restore patency in atherosclerotic coronary arteries and it has been found that different stents have different in-stent restenosis rates. It has been hypothesized that the level of vascular injury caused to a vessel by a stent determines the level of restenosis. Computational studies may be used to investigate the mechanical behaviour of stents and to determine the biomechanical interaction between the stent and the artery in a stenting procedure. In this paper, we test the hypothesis that two different stent designs will provoke different levels of stress within an atherosclerotic artery and hence cause different levels of vascular injury. The stents analysed using the finite-element method were the S7 (Medtronic AVE) and the NIR (Boston Scientific) stent designs. An analysis of the arterial wall stresses in the stented arteries indicates that the modular S7 stent design causes lower stress to an atherosclerotic vessel with a localized stenotic lesion compared to the slotted tube NIR design. These results correlate with observed clinical restenosis rates, which have found higher restenosis rates in the NIR compared with the S7 stent design. Therefore, the testing methodology outlined here is proposed as a pre-clinical testing tool, which could be used to compare and contrast existing stent designs and to develop novel stent designs.

Entities:  

Mesh:

Year:  2005        PMID: 15958213     DOI: 10.1016/j.jbiomech.2004.07.022

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  39 in total

1.  The consequences of the mechanical environment of peripheral arteries for nitinol stenting.

Authors:  Michael Early; Daniel J Kelly
Journal:  Med Biol Eng Comput       Date:  2011-08-11       Impact factor: 2.602

Review 2.  Contemporary Role of Computational Analysis in Endovascular Treatment for Thoracic Aortic Disease.

Authors:  Guido H W van Bogerijen; Jip L Tolenaar; Michele Conti; Ferdinando Auricchio; Francesco Secchi; Francesco Sardanelli; Frans L Moll; Joost A van Herwaarden; Vincenzo Rampoldi; Santi Trimarchi
Journal:  Aorta (Stamford)       Date:  2013-08-01

3.  Determination of the influence of stent strut thickness using the finite element method: implications for vascular injury and in-stent restenosis.

Authors:  Houman Zahedmanesh; Caitríona Lally
Journal:  Med Biol Eng Comput       Date:  2009-02-03       Impact factor: 2.602

4.  Mis-sizing of stent promotes intimal hyperplasia: impact of endothelial shear and intramural stress.

Authors:  Henry Y Chen; Anjan K Sinha; Jenny S Choy; Hai Zheng; Michael Sturek; Brian Bigelow; Deepak L Bhatt; Ghassan S Kassab
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-09-16       Impact factor: 4.733

5.  Mechanical Criterion for the Rupture of a Cell Membrane under Compression.

Authors:  David Gonzalez-Rodriguez; Lionel Guillou; François Cornat; Julie Lafaurie-Janvore; Avin Babataheri; Emmanuel de Langre; Abdul I Barakat; Julien Husson
Journal:  Biophys J       Date:  2016-12-20       Impact factor: 4.033

6.  A nonlinear finite element simulation of balloon expandable stent for assessment of plaque vulnerability inside a stenotic artery.

Authors:  Alireza Karimi; Mahdi Navidbakhsh; Hiroshi Yamada; Reza Razaghi
Journal:  Med Biol Eng Comput       Date:  2014-06-03       Impact factor: 2.602

7.  Computer methods for follow-up study of hemodynamic and disease progression in the stented coronary artery by fusing IVUS and X-ray angiography.

Authors:  Arso M Vukicevic; Nemanja M Stepanovic; Gordana R Jovicic; Svetlana R Apostolovic; Nenad D Filipovic
Journal:  Med Biol Eng Comput       Date:  2014-04-27       Impact factor: 2.602

8.  Behaviour of two typical stents towards a new stent evolution.

Authors:  M Simão; J M Ferreira; J Mora-Rodriguez; J Fragata; H M Ramos
Journal:  Med Biol Eng Comput       Date:  2016-09-26       Impact factor: 2.602

9.  IMPACT OF CALCIUM QUANTIFICATIONS ON STENT EXPANSIONS.

Authors:  Pengfei Dong; Hiram G Bezerra; David L Wilson; Linxia Gu
Journal:  J Biomech Eng       Date:  2018-11-15       Impact factor: 2.097

10.  Effects of stent design and atherosclerotic plaque composition on arterial wall biomechanics.

Authors:  Lucas H Timmins; Clark A Meyer; Michael R Moreno; James E Moore
Journal:  J Endovasc Ther       Date:  2008-12       Impact factor: 3.487

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.